INSTALLATION
A-3
A-3
PRO-CUT 80
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 80
GAS REQUIREMENTS
Required Gas Flow Rate
Required Gas Inlet Pressure
70 PSI @ 480 SCHF
80 to 150 PSI
(4.8 Bar. @ 13550 LHR)
(5.4 Bar. to 10.2 Bar.)
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all plasma cutting applications based on U.S. National Electrical Code
Ambient Temperature 30°C or Less
AC Input Voltage
Fuse (Super Lag)
Type 75°C
at
Circuit Breaker
Copper Wire in Conduit AWG
60 Hertz
(Delay Type)
(IEC) Sizes
230VAC Single Phase
100 Amps
#4 (21.1mm
2
)
#4 (21.1mm
2
)
460VAC Single Phase
60 Amps
#8 (8.4mm
2
)
#8 (8.4mm
2
)
230VAC Three Phase
60 Amps
#8 (8.4mm
2
)
#8 (8.4mm
2
)
460VAC Three Phase
40 Amps
#10 (5.3mm
2
)
#10 (5.3mm
2
)
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight with
Torch Cable
16.5 Inches
13.75 Inches
29.5 Inches
98 lbs. (44.5 kg.)
419 mm
349 mm
749 mm
(25 ft. cable)
113 lbs. (51.4 kg.)
(50 ft. cable)
Summary of Contents for PRO-CUT 80
Page 24: ...NOTES B 10 B 10 PRO CUT 80...
Page 40: ...NOTES E 10 E 10 PRO CUT 80...
Page 98: ...NOTES F 58 F 58 PRO CUT 80...