TROUBLESHOOTING & REPAIR
F-19
F-19
PRO-CUT 80
6. Check for the appropriate voltages outlined
in Table F.3.
NOTE:
Voltages may vary with the input line
voltage.
NOTE:
If the capacitor voltage is too high
(over 400 VDC) or too low (less than 220
VDC) the control board will deactivate relay
CR1 + CR2. This will prevent output.
7. If the test voltages do not meet the expect-
ed values as listed in Table F.3, the capaci-
tors or other components on the power
board may be faulty. Replace.
NOTE:
If the capacitor voltages are NOT bal-
anced within 20 VDC, the capacitors may need
“conditioning.” See the
Maintenance
section.
PRIMARY POWER BOARD RESISTANCE TEST AND
CAPACITOR VOLTAGE TEST
(continued)
EXPECTED VOLTS
DC AT CAPACITOR
INPUT APPLIED
TERMINALS
460VAC
325VDC
440VAC
311VDC
415VAC
293VDC
380VAC
269VDC
TABLE F.3 - CAPACITOR VOLTAGES
NOTE:
If Capacitor C1 is found to be defective, both Capacitors C1 and C2 must be replaced
at the same time. The capacitors must be replaced in matched sets.