INSTALLATION
A-3
A-3
PRO-CUT 55
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 55
GAS REQUIREMENTS
Required Gas Flow Rate
Required Gas Inlet Pressure
70 PSI @ 360 SCHF
80 to 150 PSI
(4.8 Bar. @ 10160 LHR)
(5.4 Bar. to 10.2 Bar.)
(6 CFM)
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all plasma cutting applications based on U.S. National Electrical Code
Ambient Temperature 30°C or Less
AC Input Voltage
Fuse (Super Lag)
Type 75°C
at
Circuit Breaker
Copper Wire in Conduit AWG
60 Hertz
(Delay Type)
(IEC) Sizes
2 Input Supply Wires
1 Ground Wire
230VAC Single Phase
70 Amps
#8 (8.4mm
2
)
#10 (5.3mm
2
)
460VAC Single Phase
40 Amps
#8 (8.4mm
2
)
#10 (.3mm
2
)
230VAC Three Phase
40 Amps
#10 (5.3mm
2
)
#10 (5.3mm
2
)
460VAC Three Phase
20 Amps
#10 (5.3mm
2
)
#10 (5.3mm
2
)
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight with
Torch Cable
12.6 Inches
11.0 Inches
26.0 Inches
70 lbs. (32 kg.)
320 mm
280 mm
660 mm
(25 ft. cable)
85 lbs. (39 kg.)
(50 ft. cable)