![Lincoln Electric Pro-Cut 55 Service Manual Download Page 72](http://html1.mh-extra.com/html/lincoln-electric/pro-cut-55/pro-cut-55_service-manual_1918524072.webp)
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
TROUBLESHOOTING & REPAIR
F-35
F-35
PRO-CUT 55
(T2) AUXILIARY TRANSFORMER TEST
(continued)
FIGURE F.8 – T2 AUXILIARY TRANSFORMER
PLUG J22
PLUG J21
T2 AUXILIARY
TRANSFORMER
PLUG J21
PLUG J22 (6 Cavity)
9
8
6
5
4
2
6
4
3
1
(H5)
(H2)
(H4)
(H3)
(H1)
2
7
8
2
1
5
(H5)
(H4)
(H2)
(H3)
(H1)
PLUG J22 (8 Cavity)
PROCEDURE
1. Remove main input power to the Pro-Cut 55
machine.
2. Perform
the
Input Filter Capacitor
Discharge Procedure
detailed earlier in this
section.
3. Locate the auxiliary transformer just behind
the input line switch on the lower right side of
the machine.
4. Locate and disconnect plugs J21 and J22
from the wiring harness. Cut any necessary
cable ties. See Figure F.8.
5. Carefully apply the 230 VAC isolated supply
to leads H1 (1J22) and H3 (2J22) of the aux-
iliary transformer. These leads are located in
plug J22.
6. Carefully check for the presence of the fol-
lowing primary and secondary voltages at the
appropriate leads at plugs J21 and J22. See
Figure F.8 and
Table F.6..