![Lincoln Electric Pro-Cut 55 Service Manual Download Page 104](http://html1.mh-extra.com/html/lincoln-electric/pro-cut-55/pro-cut-55_service-manual_1918524104.webp)
TROUBLESHOOTING & REPAIR
F-67
F-67
PRO-CUT 55
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
FIGURE F.25 – INPUT RECTIFIER LEAD LOCATIONS
#207
#207A
#209
A
B
C
CAP HEAD
MOUNTING
SCREW
INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT
(continued)
PROCEDURE
1. Remove input power to the Pro-Cut 55.
2. Perform
the
Input Filter Capacitor
Discharge Procedure
detailed earlier in this
section.
3. Locate the input rectifier and the leads con-
nected to it. See Figure F.25.
4. Identify and mark the leads connected to the
rectifier terminals.
5. With the phillips head screw driver, remove
the lead terminals connected to the rectifier
terminals.
6. Using the 3/16” allen wrench, remove the two
cap head screws and washers mounting the
input rectifier bridge to the center panel
assembly.