background image

English 10 English 

Technical Specifications 

 

POWER WAVE

® 

 S350CE 

POWER SOURCE – INPUT VOLTAGE AND CURRENT 

Model 

Duty Cycle 

Input Voltage 

Input Amperes 

Idle Power 

Power Factor @ 

Rated Input 

K2823-2 

40% 

230/380-415/460/575 

50/60 Hz 

35/20/17/14 

300 W Max. 

(fan on) 

0,95 

100% 28/16/14/11 

RATED OUTPUT 

Input Voltage/ Phase 

/ Frequency 

GMAW

 

SMAW (STICK) 

GTAW (TIG)-DC 

40%  60% 100% 40%  60% 100% 40%  60% 100% 

230/3/50/60 

380-415/3/50/60 

460/3/50/60 
575/3/50/60 

350A / 

31,5V 

320A / 

30V 

300A / 

29V 

325A / 

33V 

275A / 

31V 

250A / 

31V 

350A / 

24V 

325A / 

23V 

300A / 

22V 

RECOMMENDED INPUT WIRE AND FUSES SIZES

1

 

Input Voltage/ 

Phase/Frequency 

Maximum Input Ampere 

Rating and Duty Cycle 

Cord Size AWG Sizes (mm

2

)

Time Delay Fuse or Breaker 

Sizes

2

 (A) 

230/3/50/60 

380-415/3/50/60 

460/3/50/60 
575/3/50/60 

35A, 40% 
19A, 40% 
17A, 40% 
14A, 40% 

8 (10) 
12 (4) 
12 (4) 

14 (2,5) 

45 
30 
25 
20 

1

 Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient. 

 

WELDING PROCESS 

Process 

Output Range (A) 

OCV (U

0

) (V) 

Mean Peak 

GMAW 

GMAW-Pulse 

FCAW 

GTAW-DC 

SMAW 

5 – 350A 

40-70V 
40-70V 
40-70V 

24V 
60V 

100V 

PHYSICAL DIMENSIONS 

Model 

Height (mm) 

Width (mm) 

Depth (mm) 

Weight (kg) 

K2823-2 518  356  630  46.6 

TEMPERATURE RANGES 

Operating Temperature Range (ºC) 

Storage Temperature Range (ºC) 

-20 to +40 

-40 to +80 

IP23 155º(F) Insulation Class 

 

Summary of Contents for POWER WAVE S500 CE

Page 1: ...IM2034 11 2016 REV02 POWER WAVE S350 CE S500 CE OPERATOR S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St Clair Ave Cleveland Ohio 44117 1199 USA www lincolnelectric eu...

Page 2: ...Sales code K2823 code may also contain prefixes and suffixes K3168 code may also contain prefixes and suffixes K2921 code may also contain prefixes and suffixes Is in conformity with Council Directiv...

Page 3: ...er For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial Number Date Wh...

Page 4: ...rface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magn...

Page 5: ...recommended because normal air flow may be restricted Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown This machine has a protection rating of...

Page 6: ...uring this time period the user interface will not be active Product Description The POWER WAVE S350 S500 CE is a high performance multi process machine with GMAW FCAW SMAW DC TIG and pulse capability...

Page 7: ...d If Sense Leads ARE NOT Used Avoid common current paths Current from adjacent arcs can induce voltage into each other s current paths that can be misinterpreted by the power sources and result in arc...

Page 8: ...e lead 1 Neither sense lead picks up the correct work voltage causing starting and welding arc instability WORK 1 SENSE 1 1 2 WORK 2 SENSE 2 ARC 1 ARC 2 CF CF BETTER Sense lead 1 is only affected by c...

Page 9: ...ing adjustments See Accessories Section for Kits and Options available to use with the POWER WAVE S350 S500CE Definition of Welding Modes Non Synergic Welding Modes A Non synergic welding mode require...

Page 10: ...tage is the best average voltage for a given wire feed speed but may be adjusted to preference When the wire feed speed changes the POWER WAVE S350 S500CE automatically adjusts the voltage level corre...

Page 11: ...iately and repaired Routine maintenance everyday Check condition of insulation and connections of the work leads and insulation of power lead If any insulation damage exists replace the lead immediate...

Page 12: ...and telephone cables that are in or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipmen...

Page 13: ...PUT WIRE AND FUSES SIZES1 Input Voltage Phase Frequency Maximum Input Ampere Rating and Duty Cycle Cord Size AWG Sizes mm 2 Time Delay Fuse or Breaker Sizes2 A 230 3 50 60 380 415 3 50 60 460 3 50 60...

Page 14: ...ND FUSES SIZES 1 Input Voltage Phase Frequency Maximum Input Ampere Rating and Duty Cycle Cord Size AWG Sizes mm 2 Time Delay Fuse or Breaker Sizes 2 A 230 3 50 60 380 415 3 50 60 460 3 50 60 575 3 50...

Page 15: ...m K10420 1 COOLANT ACOROX 2X5L K10095 1 15M Remote control 6 pins 15m K870 FOOT AMPTROL K2909 1 6 Pin F to 12 Pin M CE Adapter for Remote Applications 0 5m K14091 1 REMOTE MIG LF45PWC300 7M KP10519 8...

Reviews: