INSTALLATION
A-19
A-19
NA-3 AND NA-4
FIGURE A.16 – CONNECTION OF NA-4 (WHICH HAS RHEOSTAT
FOR CURRENT CONTROL) TO AN AC-1200.
CLEVELAND, OHIO U.S.A
ELECTRIC
SHOCK
CAN KILL
TURN OFF INPUT POWER
TO THE WELDING POWER
SOURCE USING THE
DISCONNECT SWITCH
BEFORE WORKING
ON THIS EQUIPMENT.
WARNING
R
ELECTRODE CABLE TO
AUTOMATIC CONNECTION BAR
CONTROL CABLE
TO WORK
WORK
ELECTRODE
A
B
C
4
31
GND
2
32
21
AC-1200
21
4
31
LENGTH
2
32
75
76
77
TO AUTOMATIC
CONTROL BOX
N.C.
N.B.
TAPE UP
BOLTED
CONNECTIONS
N.A.
AND
N.D.
N.D.
N.D.
CONNECT THE CONTROL CABLE GROUND LEAD TO THE FRAME TERMINAL MARKED NEAR THE POWER SOURCE TERMINAL STRIP. THE
POWER SOURCE GROUNDING TERMINAL STRIP (MARKED AND LOCATED NEAR THE POWER SOURCE INPUT POWER CONNECTIONS)
MUST BE PROPERLY CONNECTED TO ELECTRICAL GROUND PER THE POWER SOURCE OPERATING MANUAL.
N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
N.B. EXTEND LEAD #21 USING #14 AWG OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S16586-[ ]
REMOTE VOLTAGE SENSING WORK LEAD IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE, KEEPING
IT ELECTRICALLY SEPARATE FROM THE WELDING WORK LEAD CIRCUIT AND CONNECTION. FOR CONVENIENCE, THIS EXTENDED LEAD
#21 SHOULD BE TAPED TO THE WELDING WORK LEAD.
N.C. IF USING AN OLDER CONTROL CABLE, CONNECT LEADS #75, #76, AND #77 TO LEADS #75, #76, AND #77 OF THE TERMINAL STRIP,
RESPECTIVELY.
N.D. TO AVOID POSSIBLE INDUCED NA-4 METER READING ERROR, KEEP THE CONTROL LEADS, INCLUDING THE EXTENDED LEAD #21
SEPARATED FROM THE AC WELDING CABLES BY AT LEAST 12 IN. (305 MM).