INSTALLATION
A-8
A-8
NA-3 AND NA-4
NA-3S
1. Use either a constant current or
constant voltage power supply as
required for the application. Be sure
the power source is set for constant
current or constant voltage welding as
appropriate per instructions in the
power source operating manual.
2. Set the wire feeder for constant
current or constant voltage as
appropriate per the applicable
diagram, Figures A.7 to A.18.
3. Connect the input cable to the power
source exactly as specified on the
appropriate wiring diagram, Figures
A.7 to A.18. Include all jumpers on
the terminal strips as shown on the
applicable wiring diagram.
NOTE: Paralleling two power sources of the
same model may be practical. Request
bulletin E1.30 from Lincoln Electric for
instructions.
4. Connect the work leads of sufficient
size and length (per Table A.1)
between the “To Work” stud on the
power source and the work. Be sure
the connection to the work makes
tight, clean, metal-to-metal contact.
5. Connect the two electrode cables of
the input cable assembly to the left
side (when facing the front of the
control box) of the shunt/current relay
assembly located on the back of the
control box. (Refer to Table A.1)
6. Insert the polarized connector of the
control cable into the matching
receptacle on the side of the control
box.
NA-4
1. Present NA-4s with a potentiometer-
type current control (K248 above
code 7560) are designed for use with
the AC-1200 power source. They may
be used with the discontinued
AC-1000s or AC-750s but would
require an external switch to control
transformer output. See the diagram
in Figure A.15.
2. Discontinued NA-4s equipped with a
toggle switch type current control
(K211 below code 7560) may be
connected directly to the discontinued
AC-1000s or AC-750s provided the
proper control cable is available
(K216). Contact the factory for
connection diagram S15269. These
units also may be used with the
AC-1200 but would require an
external rheostat for current control
(K775). Refer to diagram S15667 in
the IM-283 manual or request it from
the factory.
3. Connect the input cable to the power
source exactly as specified on the
appropriate wiring diagram, Figures
A.7 to A.18. Include all jumpers on
the terminal strips as shown on the
applicable wiring diagram.
NOTE: Paralleling two power sources of the
same model may be practical. Request
bulletin E1.30 from Lincoln Electric for
instructions.
4. Connect the work leads of sufficient
size and length (per Table A.1)
between the “To Work” stud on the
power source and the work. Be sure
the connection to the work makes
tight, clean, metal-to-metal contact.