Lincoln Electric K126-10 Innershield Operator'S Manual Download Page 12

A-5

INSTALLATION   

K126-[ ] INNERSHIELD® PRO

A-5

K466-4 Installation (For Hobart feeders; i.e. 27...)

    1.  Remove brass cable connector (see Figure A.2)

from the K466-4 kit and screw it on to the feeder

end of the gun cable.  Tighten the connector

with the wrench provided.

    2.  Attach the phone plug connector of the gun

control cable provided to the trigger connector

on the front of the Hobart feeder.

K466-5 Installation (For L-Tec feeders equipped

with an L-Tec feeder connector assembly, MIG

35, MIG 31A, 225...)

    1.  Remove brass cable connector (see Figure A.2)

from the K466-5 kit and screw it onto the feeder

end of the gun cable. Tighten the connection

with the wrench provided.

    2.  For L-Tec machines that require trigger lead

connections to be made at a terminal strip

located within the machine (L-Tec 225), a gun

control cable with forked terminals is provided.

Connect the terminated leads to the terminal

strip.  For a machine that requires a twist-lock

gun control cable connection, continue to use

the L-Tec gun control cable provided with the 

L-Tec wire feeder connector assembly.

Connect the twist-lock plug to the proper

receptacle on the machine.

K466-6, K466-7, and K466-9 Installation

(Wirematic, Hobart Series 2000 Feeders, SP100T

Type and Power MIG)

1. Remove brass cable connector (see Figure A.2)

from the connector kit and screw it onto the feeder

end of the gun cable.  Tighten the connection with

the wrench provided.

2. Attach the gun control cable provided to the trigger

connector on the wire feeder.

K613-2, K613-7 Installation  (Tweco #5 compatible

feeders)

   1.  Remove brass cable connector from the kit and

screw it onto the feeder end of the gun cable.

Tighten the connection with the wrench

provided.

    2.  For K613-7, attach the round connector of the

gun control cable provided to the trigger

connector on the front of the Lincoln feeder.

K613-6 Installation  (Lincoln Feeders, 3/32”

diameter wire)

    1.  Remove brass cable connector and insulation

tube from the kit.  Slide the insulation tube onto

the connector from the threaded end and screw

it onto the feeder end of the gun cable.  Tighten

the connection with the wrench provided.

GUN HANDLE

CABLE

SHIELD CLAMPING SCREWS

GUN TUBE

TIP HOLDER

TIP

 INSULATOR

INSULATION TUBE

(K466-1 ONLY)

FEEDER END

CABLE HANDLE

BRASS CABLE

CONNECTOR

MOLDED GAS

PLUG

SET SCREW

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIGHT AGAINST BRASS CABLE CONNECTOR

FIGURE A.2

Summary of Contents for K126-10 Innershield

Page 1: ...ric com register Authorized Service and Distributor Locator www lincolnelectric com locator IM10045 B Issue Date Sept 12 Lincoln Global Inc All Rights Reserved For use with machines having Code Number...

Page 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Page 3: ...rs and devices in position and in good repair Keep hands hair clothing and tools away from V belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some case...

Page 4: ...to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with su...

Page 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Page 6: ...________________________________________________________ Accessories Section C Wire Feeder Connection Kits C 1 Gun Consumable Parts C 2 ________________________________________________________________...

Page 7: ...7 NOTES K126 INNERSHIELD PRO 7...

Page 8: ...85 F 40C to 85C Cable Length 10ft 3 0m 15ft 4 5m Weight 7 3 lbs 3 3 kg 11 lbs 5 kg Electrode Diameter Range 035 3 32 0 8 2 4 mm Output Range Amperes 260A 100 duty cycle 350A 60 duty cycle Wire Feed Sp...

Page 9: ...X Trigger Lead Connector X X X X X X X X X Gas Tube and Fitting X X X Connector Tools X X X X X X X X X X Wire Feeder Connector Kits up to 5 64 diameter wire Note These kits must be used with the KP4...

Page 10: ...t 072 1 9 KP2745 072R K126 11 4 5 3 32 2 4 KP2745 332R KP2908 1 KP2907 1 KP45H 322 15 KP2906 62 K613 1 15 ft 072 1 9 KP2745 072R K126 12 4 5 5 64 2 0 KP2745 564R KP2908 1 KP2907 1 KP44 564 15 KP2906 6...

Page 11: ...as the drive roll are appropriate for the electrode size being used On Lincoln feeders check that the K1500 2 gun adapter is in place 2 Fully push the brass connector end of the gun cable into the br...

Page 12: ...plug to the proper receptacle on the machine K466 6 K466 7 and K466 9 Installation Wirematic Hobart Series 2000 Feeders SP100T Type and Power MIG 1 Remove brass cable connector see Figure A 2 from the...

Page 13: ...a 9 16 gage is included on the wrench supplied with the gun 7 Replace the gun tube and tighten the clamping screw to secure it 8 Reassemble the tip holder insulator and contact tip onto the end of the...

Page 14: ...adapter and feeder outgoing guide as well as the drive rolls are appropriate for the electrode size being used 2 Fully push the brass connector end of the gun cable into the outgoing side of the feede...

Page 15: ...perate this equipment 1 Check that the welding power source is on 2 Position electrode over joint End of the electrode should be slightly off the work 3 Lower welding helmet close gun trigger and begi...

Page 16: ...K613 2 K613 3 K613 4 K613 5 none Model LN 7 LN 8 LN 9 series LN 25 0 052 max LN 742 LN 7 LN 8 LN 9 series LN 25 1 16 and larger LN 742 LF 72 LN 74 Series 10 feeders LN 15 PF 10M PF 15M Power MIG Wirem...

Page 17: ...16 0 068 0 072 5 64 3 32 10 piece pack KP2745 035R KP2745 045R KP2745 052R KP2745 116R KP2745 072R KP2745 072R KP2745 564R KP2745 332R 100 piece pack KP2745 035R B100 KP2745 045R B100 KP2745 052R B10...

Page 18: ...ER BUSHING TO BE SEATED TIGHT AGAINST BRASS CABLE CONNECTOR LINER TRIM LENGTH 9 16 14 3 mm Figure D 1 REMOVAL INSTALLATION AND TRIMMING INSTRUCTIONS FOR MAGNUM LINERS NOTE The variation in cable lengt...

Page 19: ...SIBLE CAUSE lists the obvious external possi bilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause gene...

Page 20: ...ine s wire feed speed setting is too low 3 Wire is obstructed somewhere along the wire feed path in the gun 4 Low motor voltage 5 Gun cable is coiled kinked 6 Mechanical resistance to wire feeding is...

Page 21: ...ample ESO is too short 2 Wire may be feeding inter mittently 1 Improper electrode polarity 2 Improper welding parameters or technique 1 Defective trigger contacts closed or dirty 2 Defective closed tr...

Page 22: ...ve parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa mojada l Aislese del trabajo y de la tierr...

Page 23: ...nd Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de alimentac...

Page 24: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or...

Reviews: