![Lincoln Electric INVERTEC V300-I Service Manual Download Page 61](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081061.webp)
INVERTEC V300-I
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
F-18
TROUBLESHOOTING & REPAIR
TEST PROCEDURE
1. Move Output Terminal Switch S4 to ON
position.
Adjust the output control to the minimum
setting. Place the mode control at the
SMAW (soft) position.
NOTE: This test should only be conducted
when the machine reconnect switch and
jumper are set for high voltage (above 380
VAC) and the proper line voltage is applied.
DYNAMIC CAPACITOR BALANCE TEST
ELECTRIC SHOCK can kill.
Observe all safety precautions detailed
throughout this manual.
WARNING
-
+
OUTPUT TERMINAL SWITCH S4
(ON) POSITION
LINCOLN
FIGURE F.10 — OUTPUT TERMINAL SWITCH IN ON POSITION.