![Lincoln Electric INVERTEC V300-I Service Manual Download Page 54](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081054.webp)
INVERTEC V300-I
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
F-11
TROUBLESHOOTING & REPAIR
4. Slide the through bolts toward the
Control Panel until the brackets are dis-
connected and resistors are loose. Be
careful when loosening these through
bolts, as they secure the two resistors.
As the through bolts are removed, care-
fully place the resistors and the connect-
ed wires to the side.
TEST PROCEDURE
1. Turn main power OFF.
2. Perform Input Filter Capacitor
Discharge procedure detailed in
Maintenance section.
3. Remove the two through bolts that attach
the Power/Drive Board bracket to
Protection/Input Rectifier bracket. Each
through bolt also supports a resistor.
ELECTRIC SHOCK can kill.
Observe all safety precautions detailed
throughout this manual.
– Perform input filter capaciter discharge
procedure.
WARNING
PROTECTION BOARD OUTPUT TEST
FIGURE F.4 — REMOVING THROUGH BOLTS.