E-1
THEORY OF OPERATION
iary transformer for the appropriate input
voltage.
The auxiliary transformer develops the
appropriate AC voltages to operate the
Cooling Fan, the PC boards, and a wire
feeder (if connected). See Figure E.1.
INPUT LINE VOLTAGE
The single-phase or three-phase input
power of 200, 220, 380, 415, or 440 volts
AC is connected through a line switch on
the rear panel.
A reconnect panel allows the user to switch
to low or high voltage and connect the auxil-
POWER SUPPLY OPERATION
FIGURE E.1 — INPUT POWER CIRCUITS.
1ø OR 3ø DETETCTION (H5)
LINE
SWITCH
INPUT
RECTIFIER
AC1
AC2
AC3
A-LEAD
AUXILIARY
TRANSFORMER
TO
WIREFEEDER
18VAC
24VAC
POWERBOARD
24VDC
PULSE
TRAIN
DRIVER
BOARD
PRE-CHARGE
PRE-CHARGE
2ND STEP PWM
1ST STEP PWM VOLTAGE
15VDC-CONTROL BOARD FUNCTION VOLTAGE
24VAC-THERMOSTATS-GUN TRIGGERING
LOCAL
REMOTE
METER MODE
POT
POT
PROTECTION
BOARD
<1 VDC
RIGHT SWITCH BOARD
FET MODULES
CAP
FET MODULES
FAN
1
2
3
CONTROL
BOARD
Y-Y FEEDBACK
CR1
CR2
3A
POWER SWITCH
SECTIONS
20KHZ
LEFT SWITCH BOARD
FET MODULES
CAP
FET MODULES
CURRENT
TRANSFORMER
MAIN
TRANSFORMER
CHOKE
RECTIFIER
HEATSINK
BOTTOM
1 DIODE
5 DIODES
5 DIODES
TOP
TOP
1 DIODE
CHOKE
CHOKE
SHUNT
CURRENT FEEDBACK-PROTECTION
VOLTAGE FEEDBACK
NOTE: Unshaded areas of block logic diagram are the subject of discussion.