A-1
INSTALLATION
INVERTEC V200-T
A-1
TECHNICAL SPECIFICATIONS - V200T TIG
For DC TIG Welding at 200A/20% Duty Cycle
Based on the 1996 U.S. National Electrical Code
Code
Number
10463
Volts at Rated Amperes
28
26
25
Type of Output
DC
Input Current at
Rated Output
45/23 A @ 200 A, 33/16 A @ 150 A,
25/13 A @ 120 A
Amps
200
150
120
Maximum Open
Circuit Voltage
80 V
Standard
Voltage
(1)
230/460/1/50/60
Duty Cycle
(2)
20% Duty Cycle
60% Duty Cycle
100% Duty Cycle
Output Current
Range
1 - 200 A
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Voltage /
phase/
Frequency
230/1/50/60
460/1/50/60
Input
Ampere
Rating on
Nameplate
45
23
Type 75°C
Copper Ground
Wire in Conduit
AWG (IEC)
Sizes
10 (5.2 mm2)
12 (4 mm2)
Fuse
(Super Lag)
or Breaker
Size
50
30
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
10 (5.2 mm2)
12 (4 mm2)
Height
Width
Depth
Weight
Power
10.04 in.
7.48 in.
17.32 in.
Approx. 35 lbs.
Source
255 mm
190 mm
440 mm
16 kgs.
PHYSICAL DIMENSIONS
-20°C to +40°C
-25°C to +55°C
OPERATING TEMPERATURE
STORAGE TEMPERATURE
(1) Input voltage must be within ±10% of rated value.
(2) Duty Cycle is
based on a 10 min. period.