![Lincoln Electric FLEXCUT 125 CE Safety Instruction For Use And Maintenance Download Page 35](http://html1.mh-extra.com/html/lincoln-electric/flexcut-125-ce/flexcut-125-ce_safety-instruction-for-use-and-maintenance_1918945035.webp)
8695 4496 / B
F - MAINTENANCE
FLEXCUT 125 CE INSTALLATION
F-31
2.4
Other faults
Fault
Probable causes
Possible remedies
The tool-holder does not move
The torch has not been selected
Lower limit switch (UI alarm)
Probe impact (UI alarm)
Upper limit switch (no alarm)
Select the torch manually
Correct the fault and set the tool
holder position if required.
Correct the fault and clear the
alarm
Correct the fault and set the tool
holder position if required.
Two torches cannot be selected
The two torches are not identical
(type)
Select two identical torches
Cutting cannot be started
Lack of extraction or ineffective
extraction
Start/clean the extraction before
cutting
Cutting is not correct
Several possible causes.
Refer to the process training
manual
Incorrect cutting height
The tool holder speed offset has
not been set.
The plate is not on fixed supports
Set the speed offset of the
variable speed drive
Reposition the plate or change
the detection method (using pilot
arc)
Summary of Contents for FLEXCUT 125 CE
Page 16: ...C DESCRIPTION 8695 4496 B C 12 FLEXCUT 125 CE INSTALLATION...
Page 27: ...8695 4496 B D ASSEMBLY AND INSTALLATION FLEXCUT 125 CE INSTALLATION D 23...
Page 29: ...8695 4496 B E OPERATOR MANUAL FLEXCUT 125 CE INSTALLATION E 25 4 CYCLES...
Page 30: ...E OPERATOR MANUAL 8695 4496 B E 26 FLEXCUT 125 CE INSTALLATION...
Page 38: ...F MAINTENANCE 8695 4496 B F 34 FLEXCUT 125 CE INSTALLATION 6 1 MAIN PARTS...
Page 43: ...8695 4496 B F MAINTENANCE FLEXCUT 125 CE INSTALLATION F 39...