English 20 English
Menu SMAW
To enter into Menu SMAW see section Menu, descriped
above
In AC polarity only the HOT Start parameter is visible and
can be changed.
Table 11. SMAW Menu
Function
Factory Configuration
Default
Selectable Value Range
Displayed
parameter
name
Displayed
value
Arc Force
SOFT: 35%
0 – 75% (step 1%)
FRCE
Current selected
value (%)
CRISP: 75%
75 – 200% (step 1%)
Hot Start
SOFT: 30%
0 – 75% (step 1%)
HSTR
Current selected
value (%)
CRISP: 50%
50 – 200% (step 1%)
Stick Polarity
DC+
DC+ or DC-
STPL
Current selected
value (-)
ARC FORCE and HOT START
With those two parameters, user can change the
behaviour of unit in STICK DC stick welding. See DC stick
welding for a better understanding of both features.
STICK POLARITY
With this function is possible to change polarity of the
electrode clamp without any change in work cables
connections. For default stick polairity is DC+.