A-10
INSTALLATION
AIR VANTAGE
®
600X-I
ACCESSORY CONNECTION DIAGRAMS
Shut off welder before making or removing any electrical
connections.
When connecting an accessory to the Air Vantage
®
600X-I, the
following steps should be taken:
• Shut off the welder.
• Connect your leads for the desired accessory. For electrode
positive, connect the electrode cable to the “+” terminal of
the welder and work cable to the “-” terminal of the welder.
For electrode negative, connect the electrode cable “-”
terminal of the welder and work cable to the “+” terminal of
the welder. Installation diagrams for common setups are
included on the following pages.
• Set the WIRE FEEDER VOLTMETER switch to either “+” or “-”
as required by the electrode type (See Figure A.6).
• The switch positions on the Air Vantage
®
600X-I will be
dependent on the type of accessory chosen. Reference Table
A.4 and Figure A.6 for guidance on how to properly set up
each accessory.
WARNING
FIGURE A.5
Weld Mode
Selector
Switch
42V / 120V Wire Feeder
Voltage Switch
Weld Terminals
Switch
Local/Remote Switch
Wire Feeder Voltmeter
Polarity Switch
ACCESSORY
WELD MODE
SWITCH
WELD TERMINALS
SWITCH
LOCAL/REMOTE
SWITCH
115/42VAC
SWITCH
CrossLinc Feeder
CV
ON
REMOTE
N/A
CrossLinc Remote
Stick, Tig, Gouging
ON
REMOTE
N/A
Across The Arc Feeder
(Non CrossLinc)
CV
ON
LOCAL
N/A
42VAC Bench Feeder
w/Voltage Control
(Flex Feeds, LN-25 Dual)
CV
REMOTE
REMOTE
42VAC
42VAC Bench Feeder
w/o Voltage Control
(LF Feeders)
CV
REMOTE
REMOTE
42VAC
Submerged Arc Controllers
(NA-3, LT-7)
CV/CC
REMOTE
REMOTE
115VAC
ArcLink Feeders
(Power Feed)
ArcLink
N/A
N/A
N/A
TIG Module
TIG
REMOTE
REMOTE
N/A
Spool Gun Module
CV
ON
LOCAL
N/A
TABLE A.4