E-series AC Charger
Configuration manual V1.3
36
connect to the configured hotspot for network operation. (You can find how to
install the black cover in the 2.6 Installation steps“)
●E-series charger OCPP communication protocol can support the following
messages. If you have other needs, please contact us.
Supported messages
Type
Charger feedback
Remote Start Transaction
The server sends a
request
Send response and
execute
Remote Stop Transaction
The server sends a
request
Send response and
execute
Get Configuration
The server sends a
request
Send response and
execute
Reset
The server sends a
request
Send response and
execute
Get Diagnostics
The server sends a
request
Send response but not
execute
Update Firmware
The server sends a
request
Send response but not
execute
Change Availability
The server sends a
request
Send response and
execute
Change Configuration
The server sends a
request
Send response but not
all are executed
Clear Cache
The server sends a
request
Send response and
execute
Reserve Now
The server sends a
request
Send response and
execute
Cancel Reservation
The server sends a
request
Send response and
execute
Clear Charging Profile
The server sends a
request
Send response and
execute
Get Composite Schedule
The server sends a
request
Send response but not
execute
Set Charging Profile
The server sends a
request
Send response and
execute
Unlock Connector
The server sends a
request
Send response but not
execute
Boot Notification
The charger sends
a request.
Interpret information
and execute
Status Notification
The charger sends
a request.
Interpret information
and execute
Heartbeat
The charger sends
Interpret information