![Lincat Silverlink 600 DC04 User, Installation And Servicing Instructions Download Page 14](http://html1.mh-extra.com/html/lincat/silverlink-600-dc04/silverlink-600-dc04_user-installation-and-servicing-instructions_1917174014.webp)
IS355 ECN3592
14
Fig 5
Carry out any work necessary and reassemble in reverse order.
COMPONENT REPLACEMENT
High limit thermostat
Remove the facia panel see
(Fig 1)
.
Undo tank gland.
Undo limit thermostat nut and withdraw phial from bracket.
Withdraw phial from tank.
Thermostat can now be removed
Replace in reverse order, ensuring correct phial location within the tank bracket.
Control thermostat
Remove the facia panel see
(Fig 1)
.
Remove thermostat from the control panel.
Undo the small centre nut of the tank gland and ensure capillary is free to move.
Withdraw the thermostat phial from the tank.