IS561
Page 9 of 10
APPENDIX
TECHNICAL DATA
Model
Q2PLG
Q4PLG
Q6PLGR
No.cooking zones
2
4
7
Power / zone
– Nat Gas (G20) (kW)
5.5
Power / zone
– Propane (G31) (kW)
5.5
Power / zone
– Butane (G30) (kW)
5.5
Power / zone
– Nat Gas (G25) (kW)
5.2
Total rate
– Nat Gas (G20) (kW)
11
22
38.5
Total rate
– Propane (G31) (kW)
11
22
38.5
Total rate
– Butane (G30) (kW)
11
22
38.5
Total rate
– Nat Gas (G25) (kW)
10.4
20.8
36.4
Gas rate Nat Gas (G20) (m
3
/h)
1.05
2.10
3.67
Gas rate Propane (G31) (kg/h
-1
)
0.79
1.57
2.75
Gas rate Butane (G30) (kg/h
-1
)
0.80
1.60
2.80
Gas rate Nat Gas (G25) (m
3
/h)
0.99
1.98
3.47
Pilot Gas Rate
<250W
Power / Low
– Nat Gas (G20) (kW)
3.2
Power / Low
– Propane (G31) (kW)
3.0
Power / Low
– Butane (G30) (kW)
3.0
Power / Low
– Nat Gas (G25) (kW)
3.1
Gas rate Nat Gas (G20) (m
3
/h)
0.3
Gas rate Propane (G31) (kg/h
-1
)
0.21
Gas rate Butane (G30) (kg/h
-1
)
0.22
Gas rate Nat Gas (G25) (m
3
/h)
0.3
Burner Injector
– Nat Gas (G20)
JE40 1.41mm (Marked 400)
Burner Injector
– Propane (G31)
JE04 1.13mm (Marked 170)
Burner Injector
– Butane (G30)
JE04 1.13mm (Marked 170)
Burner Injector
– Nat Gas (G25)
JE40 1.41mm (Marked 400)
By-Pass Injector
– Nat Gas (G20)
JE138 1.41mm (Marked XN)
By-Pass Injector
– Propane (G31)
JE140 0.87mm (Marked XP)
By-Pass Injector
– Butane (G30)
JE140 0.87mm (Marked XP)
By-Pass Injector
– Nat Gas (G25)
JE138 1.41mm (Marked XN)
Supply Pressure
– Nat Gas (G20)
20mbar
Supply Pressure
– Propane (G30)
37mbar
Supply Pressure
– Butane (G30)
28-30mbar
Supply Pressure
– Nat Gas (G25)
25mbar
Gas connection
R1/2”
For those destination countries where the supply pressure exceeds the supply pressure given above, a
regulator (Lincat Ref. PG10) must be fitted and the supply pressure set to the pressure detailed.