IS744 ECN 4665
Page 5 of 5
NOTE
CHECK LIST OF ENCLOSURES
Model
PHDR01
Tick
Warranty card
1
Instructions manual
1
Pan Supports
3
Oven Shelves
2
SERIAL NUMBER
Each appliance manufactured at Lincat has a unique identifying number found in
the top right hand corner of the data plate attached at the rear of the appliance.
Please record that number in the space provided should it be required for future
reference.
Serial Number
INSTALLATION AND COMMISSIONING
Optionally site the appliance beneath an extraction canopy for the removal of
combustion products, steam and other odours associated with cooking of
products
When making the gas connection, fit an isolating cock into the supply line close
to the appliance for emergency shutdown or servicing purposes.
Installation must include sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room of
installation. There must be a minimum free area of 4.5cm
2
per kW of total heat
input.
Allow for a sufficient flow of fresh air for complete gas combustion.
Do not connect directly to any flue, ducting or mechanical extraction system.
The gas supply hose or tubing shall comply with national requirements in force
and shall be periodically examined and replaced as necessary.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
Means of isolation with at least 3mm contact separation in all poles must be incorporated
into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a temperature
rating of 60 ºC.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)