Power level settings 

 
9 power level settings are available.  The table gives the percentage of maximum 
power for each setting with the time limit for operation at that power. 
 

Power level 

Low temp 

hold 

% of power 

--- 

3% 

6% 

11%  15%  19%  31%  45%  64%  100% 

Time limit (mins) 

120 

360 

360 

300 

300 

240 

90 

90 

90 

90 

 

Power boost function 
 

Power boost is activated by turning the control clockwise from level 9.  Only one coil 
can be boosted at a time. 
 
The power boost will run for a maximum of 10 minutes before reverting to level 9.  It 
may be boosted again, providing the system internal temperatures are satisfactory. 
 

Automatic heat-up control (AHC) 

 
When activated, the AHC will give maximum power (level 9) to a coil for a preset time 
before reducing to a lower power level set by the control.  To activate, the control is 
turned anticlockwise from the ‘Off’ position briefly whilst the ‘A’ symbol illuminates: the 
control is then turned 

clockwise to set the ‘final’ required power (1-8).  The display 

reverts to the ‘A’ symbol and the hob will run at maximum power for the time shown in 
the table, before reducing power to the ‘final’ setting. 
 
Power level setting 

Preset time (secs) 

40 

72 

120 

176 

256 

432 

120 

192 

 

Control lock function 

 
This function prevents unwanted operation of the hob.  When the control lock is active, 
the ‘L’ symbol is displayed.  It is activated and de-activated by turning either control 
knob anticlockwise to the control lock position and held for approximately 5 seconds. 
 

Pan detection function 

 
This prevents the coils being turned on without a pan being present, and also turns off 
the coil as soon as a pan is removed.  If the pan is of the wrong material for induction 
equipment, the ‘no pan present’ symbol is displayed.  After use, switch off the hob via 
the control and do not rely on the pan detector. 

 
Residual heat display 

 
When the temperature of the hobtop exceeds 60

o

C after removal of a pan, the ‘H’ 

symbol displays, indicating a hot surface.  (Refer also to the error codes section).  
Whilst the residual heat display is showing, leaving the appliance connected to the 
power supply allows the cooling fans to continue to operate.  When the ‘H’ symbol is 
extinguished, switch off the power supply. 

 
 
 

Summary of Contents for PHEH01

Page 1: ...e Induction Hob PHEH01 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ________________________...

Page 2: ...uarantee 13 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure...

Page 3: ...maintenance or cleaning If the ceramic glass surface is cracked immediately disconnect the appliance from the supply Caution symbol Non ionising electromagnetic radiation magnetic field Warning symbo...

Page 4: ...nary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 Install this appliance on a level surface ensuring all vents are unobstructed Anyny adjacent partitions walls or furniture...

Page 5: ...RUCTIONS Only qualified or trained personnel should use this appliance The green neon indicates power to the unit Do not block or restrict the inlet filers or vents on the appliance Restricted airflow...

Page 6: ...ze and pan material Recommended pan base diameters Rear zone Minimum pan 120mm Maximum coil diameter 250mm Nominal coil diameter 180mm The pan should be located concentrically over the glass target ri...

Page 7: ...d Simmer functions The first three settings on the control knob are low temperature control functions One bar is melt to heat the pot to 45 C two bars is 70 C and three bars is 94 C These temperatures...

Page 8: ...e A symbol and the hob will run at maximum power for the time shown in the table before reducing power to the final setting Power level setting 1 2 3 4 5 6 7 8 Preset time secs 40 72 120 176 256 432 1...

Page 9: ...e objects on the sensors Er 20 Flash memory TC error C defective Replace TC Er 22 Button evaluation defective UI shuts off after 3 5 7 5 sec Short or open circuit in the area of the button sensor Repl...

Page 10: ...ical components Dry with a soft cloth Clean the ceramic glass with a scraper or Vileda CERAN cleaning sponge use a few drops of a suitable cleaner on a paper towel or the rough side of the sponge Wipe...

Page 11: ...ch Fig 3 and lift the filter cover away from the base Replace the used filter with a new one Reverse the procedure to re fit the cover Do not operate the appliance without a filter as dirt and grease...

Page 12: ...13 Please refer to the Service Help Desk number on the final page of this manual Part Number Description FE10 Foot FG03 Fanguard FI33 Filter pad KN523 Control knob NE43 Neon S R0079 Cooling fan FAULT...

Page 13: ...ot diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bu...

Reviews: