IS707 ECN 4277
8
Power level settings
9 power level settings are available. The table gives the percentage of maximum
power for each setting with the time limit for operation at that power.
Power level
Low temp
hold
1
2
3
4
5
6
7
8
9
% of power
---
3%
6%
11% 15% 19% 31% 45% 64% 100%
Time limit (mins)
120
360
360
300
300
240
90
90
90
90
Power boost function
Power boost is activated by turning the control clockwise from level 9. Only one coil
can be boosted at a time.
The power boost will run for a maximum of 10 minutes before reverting to level 9. It
may be boosted again, providing the system internal temperatures are satisfactory.
Automatic heat-up control (AHC)
When activated, the AHC will give maximum power (level 9) to a coil for a preset time
before reducing to a lower power level set by the control. To activate, the control is
turned anticlockwise from the ‘Off’ position briefly whilst the ‘A’ symbol illuminates: the
control is then turned
clockwise to set the ‘final’ required power (1-8). The display
reverts to the ‘A’ symbol and the hob will run at maximum power for the time shown in
the table, before reducing power to the ‘final’ setting.
Power level setting
1
2
3
4
5
6
7
8
Preset time (secs)
40
72
120
176
256
432
120
192
Control lock function
This function prevents unwanted operation of the hob. When the control lock is active,
the ‘L’ symbol is displayed. It is activated and de-activated by turning either control
knob anticlockwise to the control lock position and held for approximately 5 seconds.
Pan detection function
This prevents the coils being turned on without a pan being present, and also turns off
the coil as soon as a pan is removed. If the pan is of the wrong material for induction
equipment, the ‘no pan present’ symbol is displayed. After use, switch off the hob via
the control and do not rely on the pan detector.
Residual heat display
When the temperature of the hobtop exceeds 60
o
C after removal of a pan, the ‘H’
symbol displays, indicating a hot surface. (Refer also to the error codes section).
Whilst the residual heat display is showing, leaving the appliance connected to the
power supply allows the cooling fans to continue to operate. When the ‘H’ symbol is