The Safety thermostat can be reset by pressing the button (g) after the appliance has 
cooled down 

The gas valve control knob displays the following: Off 

1 to 5 where 1 approximates to 100

°

C and 5 approximates to 280

°

Caution:

 Ensure that the container into which the food product is emptied is suitable 

to contain food at a high temperature. 

Caution:

 The lid must be lifted fully up before operating the tank tilting mechanism. 

The tank may be raised or lowered at any time during the cooking cycle.  To do this, 
lift the lid and turn the hand wheel clockwise on the appliance to raise and empty the 
tank.  Turn the wheel counter-clockwise to lower the tank. 

Moderate the speed to obtain an even and controlled pour, this will vary depending 
on viscosity of contents 

 

Filling the tank with water 

Caution: Ensure the tank is seated correctly in the lowered position before 
adding water. 

Press the water load button to add water. 

Switching on the bratt pan 

Press and turn the valve control knob to the desired setting. Ensure simmer setting 
switch is pressed in the up position towards the larger three flames engraved on the 
facia just above the switch. 

Switching on the simmer mode 

The bratt pan has a simmer setting to be used with sensitive products that require a 
gentler heat i.e. milk or cream based recipes.  

Switch the appliance on as normal for full power to bring the product up to 
temperature.  

Switch the simmer switch to the down position when required - towards the three 
smaller flames.  

NB: The gas flame will cycle and the igniter will be heard operating, this is 
normal to obtain short bursts of power. 

Do not forget to revert to full power when the simmer setting is no longer required. 

Switching off the bratt pan 

Turn the thermostat knob to the ‘Off’ position  

Turn the appliance off at the electrical supply, and close the gas mains stopcock. 

Emptying the tank 

Prepare a suitable vessel beneath the discharge spout of the tank. 

Lift the lid. 

Slowly raise the tank by turning the wheel clockwise..  Take care not to create ‘surge’ 
of liquid contents by attempting to raise the tank too quickly. 

Summary of Contents for OG8801

Page 1: ...0 Gas Heated Tilting Bratt Pan OG8801 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...e Information and Guarantee 16 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your ...

Page 3: ... supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person Ensure that the plug socket is accessible at all times Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model OG8801 N OG8801 P Height mm 900 900 Width mm 900 900 Depth mm 800 800 Height Lid Up mm 1600 1600 Weight kg 184 184 Nominal Gas gross kW 24 5 23 0...

Page 4: ...to health in the room of installation There must be a minimum free area of 4 5cm2 per kW of total heat input Allow for a sufficient flow of fresh air for complete gas combustion Do not connect directly to any flue ducting or mechanical extraction system The gas supply hose or tubing shall comply with national requirements in force and shall be periodically examined and replaced as necessary An equ...

Page 5: ... poles must be incorporated into the fixed wiring of this appliance The fixed wiring insulation must be protected by insulated sleeving having a temperature rating of H 07 RN F Supply cords shall be oil resistant sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 The appliance must be installed in a well ventilated place and at...

Page 6: ...ble for the type of gas supplied Ensure the gas supply is provided with an isolating cock for emergency shutdown Ensure that the supply hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary These appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful t...

Page 7: ...ion of the rated thermal output When the installation and adjustment operations are complete or after performing maintenance please verify the condition of the appliance and check the rated thermal output of the appliance The rated thermal output is indicated in the table Technical Data Inspection of gas connection pressure To measure the gas connection pressure use a manometer with a minimum desi...

Page 8: ... hand wheel for tilting the pan and a button for filling with water The valve knob a sets the temperature of the tank and the gas burner ignites automatically when switched to the on position The simmer rocker switch b allows for a gentle heat once the food product has been brought to temperature This is ideal if the food is prone to burning in particular milk or cream based products Small flames ...

Page 9: ...g on the bratt pan Press and turn the valve control knob to the desired setting Ensure simmer setting switch is pressed in the up position towards the larger three flames engraved on the facia just above the switch Switching on the simmer mode The bratt pan has a simmer setting to be used with sensitive products that require a gentler heat i e milk or cream based recipes Switch the appliance on as...

Page 10: ... accessed by removing the front control panel The lid springs should be done at the same time These are accessed by removing the cover located at each end by screws Do not use a water jet or steam cleaner and do not immerse this appliance Always disconnect the appliance from the mains supply before cleaning or maintenance Steel parts can be cleaned using a cloth with water and mild detergent aggre...

Page 11: ...e controller screws Replace flame controller Control thermostat Remove control knobs and facia panel Unscrew the fixing screws and disconnect the wiring Remove the thermostat from the switch Remove rear thermostat bulb cover plate Remove the thermostat bulb from the bracket Safety thermostat Remove facia panel Unscrew the fixing screws and disconnect the wiring Remove rear thermostat bulb cover pl...

Page 12: ...connect the electrical connections of the device Replace the component Tank Remove right hand side panel and remove and replace components as necessary Water solenoid Remove the front lower control panel Remove and replace the component This appliance cannot be converted by the user CONVERSION ...

Page 13: ...ifficult uneven or unsuccessful lighting of burners Insufficient gas pressure Blocked pipe work or injector Defective gas valve Intervention of safety thermostat Thermostat defective Tank lifting micro switch defective Burners going out during use Tank not completely down Igniter lead disconnected Defective flame controller Gas valve defective Safety thermostat operated or defective Difficult or u...

Page 14: ...574 COPPER 1BA WASHER FAS658 4 X 30 ROLL HA112 SPOKED HANDWHEEL IG06 IGNITION LEAD IS582 OG8801 BRATT PAN USER INS JE71 BURNER JET G20 NATURAL GAS JE34 BURNER JET G31 PROPANE GAS KN502 OPUS 800 KNOB BRATT PAN LE14 LENS COVER LE14 NE47 AMBER NEON PL209 PLUG LEAD 3 METRE SO27 WATER VALVE NO SP92 LID SPRING SW34 SWITCH CHANGE OVER SW58 FAN SWITCH SW80 GREEN BUTTON SOLID SW82 SWITCH ELEMENT N O SW93 L...

Page 15: ...IS 582 ECN 3851 Page 15 of 17 900 900 800 770 800 770 is with lid up and flue top removed 900 1600 ...

Page 16: ...iently as possible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty given reasonable access to the appliance during normal working hours Monday to Friday 08 30 to 17 00 GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty The guarantee is in addition to a...

Page 17: ...ised technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes of administrative time not spent directly carrying out servicing work is provided for within the warranty Any requirement for staff attending the call to spend greater time than 15 minutes due to ad...

Reviews: