CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
INSTALLATION AND COMMISSIONING
Site this appliance beneath an extraction canopy for the removal of combustion
products.
When making the gas connection, fit an isolating cock into the supply line close to the
appliance for emergency shutdown or servicing purposes.
Installation must include sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room of
installation. There must be a minimum free area of 4.5cm
2
per kW of total heat
input.
Allow for a sufficient flow of fresh air for complete gas combustion.
Do not connect directly to any flue, ducting or mechanical extraction system.
The gas supply hose or tubing shall comply with national requirements in force and
shall be periodically examined and replaced as necessary.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
Install this appliance on a level surface ensuring all air vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material.
Minimum distances A 50mm B 1000mm – see Fig 1.