IS 282 ECN 3607
Page 6 of 8
D3 and D5 models have a manual temperature control (4). Turn to setting 5 and
wait 30 minutes before loading with pre-heated food. Adjust the temperature as
required.
C6 models have a digital display controller (4). Wait 30 minutes until the display
shows 85 Deg C. Load with pre-heated food. Adjustment between 75-95 Deg C is
available by pressing and holding the ‘Set’ button and using the buttons marked <<-
< and >->>.
Note: The temperature display relates to the air temperature inside the
cabinet
– not the food temperature.
Humidity feature - Fig 3
Fig 3
The integral water bath B with lid A is intended to be used to keep food moist when
the appliance is lightly loaded. Fill with warm water. To prevent condensation, do
not over-load shelves with food. Check the water level
– be aware the water bath
will become hot during use.
Adjusting shelf positions
Disconnect from electricity supply and allow appliance to cool. Slide the doors to
the centre and lift up and out of the bottom runners to remove. Remove the
shelves. Use the Allen key provided to adjust the shelf supports. At the rear, the
shelf supports are situated behind the cable panel. Remove the screws in the cable
panel and open the panel until adjustment of the shelf supports can be made.
Do
not completely remove the cable panel.
Replace the panel, ensuring cables are
not trapped.
CLEANING
Do not use a water jet or steam cleaner, and do not immerse this appliance.