mod. 514
GB
4/28
Always measure from external
equipment surface
SECURITY DISTANCES
•
From flammable object :
−
A > 400 mm
B > 100 mm
C > 100 mm
•
From flammable object and from principal wall in rein forced concrete :
−
A > 800 mm
B > 200 mm
C > 200 mm
•
The minimal distance between the stove and every object around it is 1 mt
1.4
Connection
•
Before connection check the technical data reported in the technical plate and control
that they correspond to the ones required in the order.
•
All heating biomass equipments especially wood and pellet stove have to evacuate the
combustion products in a flue, built in conformity with the normative in force
•
The following instructions describe „ informations for a good installation „ and refer to a
normative in force but they are not to be consider exhaustive for installations laws