Burner basket 

Spark tube 

Protection pellet sheet 

3

 

MAINTENANCE AND CLEANING  
RESERVED TO USER 

 

3.1

 

Ordinary Maintenance

 

 

 

The frequency of the stove cleaning and maintenance is depending from pellet quality an 
quantity.  An  high  degree  of  humidity,  ash,  powder  or  chemicals  adds    inside  the  pellet 
could  increase  the  necessary  cleaning  and  maintenance  operations;  so  we  recommend 
again to employ a very high pellet quality 

 

Burner  Tank  Cleaning

  :      To  obtain  the  best  performance  during  stove’s  functioning, 

EVERY  DAY

  it’s  necessary  to  clean  the  burner  tank.  Remove  the  tank  and  empty  it 

from every residuals, clean all the holes on the bottom and replace it into the stove being 
careful to the position of starting glow plug. 

 

 

Ash Drawer cleaning   

 

The ash drawer is placed under the foyer, open 
the fire door to enter it.  

 

Remove the ash drawer.  

 

The ash drawer has to be emptied every day from 
combustion residuals employing the glove. This 
operation has to be done with cold stove.  

 

Attention please to embers or hot pieces.  

 

Insert again the ash drawer into its place and 
close the fire door.  

 

To forget to insert the ash drawer in its place it’s 
dangerous.  

 

 

Ordinary  Cleaning  about  combustion 
room

.

.

  The  combustion  room  has  to  be 

checked  to  insure  that  air  feed  is  regular. 
The combustion room can be cleaned with a 
vacuum cleaner. To scrape off the scale with 
the appropriate piece of equipment . 

 
 
 

 

After  having  remove  the  burner  basket  to 
scrape off the scale, replace it verifying that 
the  hole  of  big  dimension  has  to  be 
correspondence with glow up tube. 

 

Check that the protection pellet sheet should 
be placed on to the burners..   

 
 
 
 
 

Ash Drawer 

Fire Door 

Summary of Contents for Perla 514

Page 1: ...Residential space heating appliances fired by wood pellets 1 28 Perla Mod 514 USING INSTRUCTIONS AND MAINTENANCE Equipments built in conformity with European Norms for the marking Cod 90003133 Rev 2...

Page 2: ...IMPROPER USE of theequipment and therefore UNCORRECTLY UTILIZATION with possiblyofdecay ofthe guarantee INDEX Chap Description Pag 1 Installation 3 1 1 Normative and prescriptions 3 1 2 Preliminary o...

Page 3: ...d The installation must be carried out and certified according to the normative in force regarding installations exhaust fumes connections electricity water ventilation suction The manufacturer discla...

Page 4: ...1 mt 1 4 Connection Before connection check the technical data reported in the technical plate and control that they correspond to the ones required in the order All heating biomass equipments especia...

Page 5: ...ction or path it will be necessary a complete inspection of exhaust fumes system It s advisable that the flue should be supplied by a chamber for solid material and condenses collection placed under t...

Page 6: ...mod 514 GB 6 28 Hereby some suggested schemes regarding the exhaust of the combustion products Insulated Flue Insulated Flue Masonry insulated flue Masonry insulated flue...

Page 7: ...CTION TO FLUE The connect the heating equipment to the flue chimney checking that the exhaust pipe don t take up the free section of flue Employ only tubes supplied by seal gasket Limitate the use of...

Page 8: ...e right exit of combustion products with any type of wind Positioned to guarantee the right fumes dispersion especially out of re flux area This area has several dimensions and conformations in functi...

Page 9: ...follows Measure and draw with real dimension on the wall the points for stove connection Realize the hole on the wall Connect the stove to the flue with the tube for exhaust fume In case that the exh...

Page 10: ...cted directly with installation environment c Protected with grate or lath attention to not reduce the min section required on point a and placed so that to avoid obstruction The air inflow can be als...

Page 11: ...AS TEMPE RATURE NOMINAL POWER OUTPUT C 238 7 REDUCED POWER OUTPUT C 143 6 FUME CHIMNEY QUANTITY m NOMINAL POWER OUTPUT g s 5 5 REDUCED POWER OUTPUT g s 3 5 COMBUSTIBLE CONSUMPTION MAX kg h 1 42 COMBUS...

Page 12: ...window is broken and or damaged or in case of bad functioning the stove can not be lighted till the problem has be solved The operation of the machine must always happen under surveillance To disconne...

Page 13: ...uring the first heatings you can notice the following situations During the first ignitions the appliance may exhale bad smell We suggest a good aeration of the room till bad smells have been eliminat...

Page 14: ...ich will be visualized on display with the following marks FAN ACC Glow plug pre heating phase LOAD WOOD Pellets Loading phase FIRE ON Combustion Pellets phase ON ECO Power function phase Display Equi...

Page 15: ...t pushing button 4 for several seconds on panel control 3 Remove the current through the back button 0 1 4 Remove pellets from burner tank 5 Recover the current through the back button 6 Repeat from p...

Page 16: ...F ut 06 Blowing out time 1st cycle 00 00 23 50 OFF ut 07 Activation Deactivation program 1st cycle on 1 7 off 1 7 ut 08 Starting time 2nd cycle 00 00 23 50 OFF ut 09 Blowing out time 2nd cycle 00 00 2...

Page 17: ...ignition time F Push the button 3 SET till on display appears the initials Use the button 1 and 2 to program the turning off hour desired and the Button 3 SET to confirm To set up OFF to not have a s...

Page 18: ...rograms to select ut01 and the current day It s possible to carry out manual Ignition Turning Off even with active programs which will start up and turn off during predetermined hour at the same To us...

Page 19: ...care to keep clean the basket burner only after this checking period You can modify again the regulation Increase the pellets quantity Reduce the pellets quantity 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8...

Page 20: ...ove automatically The stove should be lighted on again after a pause of 45 min for cooling If this situation will repeated please call the assistance service Extinction for low temperature If the stov...

Page 21: ...glow plug Ash Drawer cleaning The ash drawer is placed under the foyer open the fire door to enter it Remove the ash drawer The ash drawer has to be emptied every day from combustion residuals employi...

Page 22: ...the appliance of the fumes exhaust ducts and of the chimney In case of a long time of non utilization of the appliance before lighting the stove verify that fume exhaust ducts and chimney are not obst...

Page 23: ...The thermostat take part Bad quality Pellet Low Pellet feed To load pellet tank Read info about not introduction pellet Let the stove turned off When the stove is cold try to start it again To check t...

Page 24: ...o fire bearing No Pellets feed Glow plug breaking No fire bearing from fumes feeler Pellets with ignition difficult To check Pellets tank level To check the screw feeder function To check electrical c...

Page 25: ...ling Tension break off Wait for the automatic ignition ON 1 5 on t The temperature in the room is not found The environment feeler is broken Check the environment feeler Substitute the environment fee...

Page 26: ...______________________________________________________________________ ___________________________________________________________________________ _____________________________________________________...

Page 27: ...______________________________________________________________________ ___________________________________________________________________________ _____________________________________________________...

Page 28: ...4 GB 28 28 4 Technical data plate You find here enclosed a copy of technical data plate Lincar S p A Via E Fermi 5 42046 Reggiolo RE Italy Tel 39 0522 972260 Fax 39 0522 973625 www lincar it info linc...

Reviews: