Possible failure and its solution 

 

DEFECT 

POSSIBLE CAUSE 

SOLUTION 

The flame is weak and 
orange colour, the pellet 
accumulate inside tank 
and door window is full 
of ash. 

Insufficient combustion 
air. 
 
 
 
 
 
 
 
 

 

Too much pellets fall 
down in the basket burner  
 

 

To clean the combustion basket 
and to scrape off the scale to avoid 
obstructions to change air. Employ 
pellet of good quality.. 

 

To check that the air combustion 
circulation is not osbtructed by 
ash. 

 

To check if the air tube or exhaus 
fumetube are obstructed. 

 

To cheack the seal of fire door. 

 

To call the qualify staff. 

 

To check the combustion as 
described preceding.  

 

To call the assistance centre to 
make the regulations. 

The flame turn off and 
the stove automatically 
blowing out. 

 

Pellet tank in empty. 

 

Pellet are not 
introduced. 

 

The thermostat take part. 

 

 

Bad quality Pellet. 

 
 

 

Low Pellet feed. 

 

To load pellet tank. 

 

Read info about not introduction 
pellet. 

 

Let the stove turned off. When the 
stove is cold try to start it again. 

 

To check the regulation from Your 
assistance centre. Repeat 1 cycle 
of starting. 

 

To regulate the combustion 
through the pellets correction (see 
the chapter Combustion 
Regulation)  

 

To require intervention specialist 
staff. 

Pellet are not introduced. 

 

Pellet tank is empty. 

 

Screw Feeder or electric 
card are defective. 

 

 

Screw feeder is 
obstructed.

 

 

To check the tank and to load it. 

 

To check the apparatus from 
assistance centre and to substitue 
with original spare parts. 

 

To clean the tank and screw 
feeder. 

The stove blowing out 
after few min. 

Exhaus gas has not joint 
the necessary temperature. 

 

Try to start it again. 

 

Control Pannel  doesn‘t 
turn on. 

The stove doesn‘t receive 
electricity. 

 

To check the stove plug. 

 

To check the general switch will 
be on 1 position. 

 

To check and substitue the fuse on 
electric card. 

Summary of Contents for Perla 514

Page 1: ...Residential space heating appliances fired by wood pellets 1 28 Perla Mod 514 USING INSTRUCTIONS AND MAINTENANCE Equipments built in conformity with European Norms for the marking Cod 90003133 Rev 2...

Page 2: ...IMPROPER USE of theequipment and therefore UNCORRECTLY UTILIZATION with possiblyofdecay ofthe guarantee INDEX Chap Description Pag 1 Installation 3 1 1 Normative and prescriptions 3 1 2 Preliminary o...

Page 3: ...d The installation must be carried out and certified according to the normative in force regarding installations exhaust fumes connections electricity water ventilation suction The manufacturer discla...

Page 4: ...1 mt 1 4 Connection Before connection check the technical data reported in the technical plate and control that they correspond to the ones required in the order All heating biomass equipments especia...

Page 5: ...ction or path it will be necessary a complete inspection of exhaust fumes system It s advisable that the flue should be supplied by a chamber for solid material and condenses collection placed under t...

Page 6: ...mod 514 GB 6 28 Hereby some suggested schemes regarding the exhaust of the combustion products Insulated Flue Insulated Flue Masonry insulated flue Masonry insulated flue...

Page 7: ...CTION TO FLUE The connect the heating equipment to the flue chimney checking that the exhaust pipe don t take up the free section of flue Employ only tubes supplied by seal gasket Limitate the use of...

Page 8: ...e right exit of combustion products with any type of wind Positioned to guarantee the right fumes dispersion especially out of re flux area This area has several dimensions and conformations in functi...

Page 9: ...follows Measure and draw with real dimension on the wall the points for stove connection Realize the hole on the wall Connect the stove to the flue with the tube for exhaust fume In case that the exh...

Page 10: ...cted directly with installation environment c Protected with grate or lath attention to not reduce the min section required on point a and placed so that to avoid obstruction The air inflow can be als...

Page 11: ...AS TEMPE RATURE NOMINAL POWER OUTPUT C 238 7 REDUCED POWER OUTPUT C 143 6 FUME CHIMNEY QUANTITY m NOMINAL POWER OUTPUT g s 5 5 REDUCED POWER OUTPUT g s 3 5 COMBUSTIBLE CONSUMPTION MAX kg h 1 42 COMBUS...

Page 12: ...window is broken and or damaged or in case of bad functioning the stove can not be lighted till the problem has be solved The operation of the machine must always happen under surveillance To disconne...

Page 13: ...uring the first heatings you can notice the following situations During the first ignitions the appliance may exhale bad smell We suggest a good aeration of the room till bad smells have been eliminat...

Page 14: ...ich will be visualized on display with the following marks FAN ACC Glow plug pre heating phase LOAD WOOD Pellets Loading phase FIRE ON Combustion Pellets phase ON ECO Power function phase Display Equi...

Page 15: ...t pushing button 4 for several seconds on panel control 3 Remove the current through the back button 0 1 4 Remove pellets from burner tank 5 Recover the current through the back button 6 Repeat from p...

Page 16: ...F ut 06 Blowing out time 1st cycle 00 00 23 50 OFF ut 07 Activation Deactivation program 1st cycle on 1 7 off 1 7 ut 08 Starting time 2nd cycle 00 00 23 50 OFF ut 09 Blowing out time 2nd cycle 00 00 2...

Page 17: ...ignition time F Push the button 3 SET till on display appears the initials Use the button 1 and 2 to program the turning off hour desired and the Button 3 SET to confirm To set up OFF to not have a s...

Page 18: ...rograms to select ut01 and the current day It s possible to carry out manual Ignition Turning Off even with active programs which will start up and turn off during predetermined hour at the same To us...

Page 19: ...care to keep clean the basket burner only after this checking period You can modify again the regulation Increase the pellets quantity Reduce the pellets quantity 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8...

Page 20: ...ove automatically The stove should be lighted on again after a pause of 45 min for cooling If this situation will repeated please call the assistance service Extinction for low temperature If the stov...

Page 21: ...glow plug Ash Drawer cleaning The ash drawer is placed under the foyer open the fire door to enter it Remove the ash drawer The ash drawer has to be emptied every day from combustion residuals employi...

Page 22: ...the appliance of the fumes exhaust ducts and of the chimney In case of a long time of non utilization of the appliance before lighting the stove verify that fume exhaust ducts and chimney are not obst...

Page 23: ...The thermostat take part Bad quality Pellet Low Pellet feed To load pellet tank Read info about not introduction pellet Let the stove turned off When the stove is cold try to start it again To check t...

Page 24: ...o fire bearing No Pellets feed Glow plug breaking No fire bearing from fumes feeler Pellets with ignition difficult To check Pellets tank level To check the screw feeder function To check electrical c...

Page 25: ...ling Tension break off Wait for the automatic ignition ON 1 5 on t The temperature in the room is not found The environment feeler is broken Check the environment feeler Substitute the environment fee...

Page 26: ...______________________________________________________________________ ___________________________________________________________________________ _____________________________________________________...

Page 27: ...______________________________________________________________________ ___________________________________________________________________________ _____________________________________________________...

Page 28: ...4 GB 28 28 4 Technical data plate You find here enclosed a copy of technical data plate Lincar S p A Via E Fermi 5 42046 Reggiolo RE Italy Tel 39 0522 972260 Fax 39 0522 973625 www lincar it info linc...

Reviews: