mod. G02
23/72
Top burners
•
To unscrew the nozzles of the plan burners and to replace them with those adapted to the
type of used gas consulting table 1.
Tab. 1
Burner
Methane
G20
Butane/Propane
G30/G31
kW 7.25
200
132
kW 6.0
180
125
kW 3.5
145
95
Oven kW 8.4
220
140
Maxi oven Kw 11
280
170
•
To extract the nozzles spy pilot burners inserted on particular
illustrated plan in the figure, to unscrew the gas tube
connected to spy; it’s advisable to use contemporary the
spanner nr.10 and nr.12.
•
To substitute the nozzle of spy pilot plan burners with the one
adapted to the type of used gas consulting table 2.
Tab. 2
Methane
G20
Butane/Propane
G30/G31
35
20
•
To regulate the minimum of burners with the by-pass screw as indicated on figure: for
BUTANE/PROPANE gas (G30/G31) the screw must be screwed till the bottom;
for gas METHANE (G20)
place the burners knob to regulate, in minimum position
with the burner light up, to unscrew anticlockwise the by-
pass screw to obtain a minimum steady flame. The burner
flame’s must remain ignited also in the passages from
maximum to minimum without cause backfires.
•
After the regulation seal the by pass with varnish.
By-pass