Page 37 of 44
Read Only Registers (Input
Registers)
Parameter list version
1.1
Address
Term
Para-
meter
Remark
Type
Min.
limit
Max. limit
High/
Low
Order
40
Number of Telegrams
With Invalid Content
61
Service counter (invalid function code, invalid data etc.)
used for debugging on system level. Also available via
the BusLink service tool
U32
0
4294967295
(15:0)
41
Number of Telegrams
With CRC Error
62
Service counter (total of corrupted telegrams) used
for debugging on system level. Also available via the
BusLink service tool
U32
0
4294967295
(31:16)
42
Number of Telegrams
With CRC Error
62
Service counter (total of corrupted telegrams) used
for debugging on system level. Also available via the
BusLink service tool
U32
0
4294967295
(15:0)
43
Total Number of Current
Cut-Offs out
78
Service counter. Also available via the BusLink service
tool
U32
0
4294967295
(31:16)
44
Total Number of Current
Cut-Offs out
78
Service counter. Also available via the BusLink service
tool
U32
0
4294967295
(15:0)
45
Total Number of Current
Cut-Offs in
79
Service counter. Also available via the BusLink service
tool
U32
0
4294967295
(31:16)
46
Total Number of Current
Cut-Offs in
79
Service counter. Also available via the BusLink service
tool
U32
0
4294967295
(15:0)
47
Number of Times Run-
ning With Actuator
Temperature Exceeded
80
Service counter. Also available via the BusLink service
tool
U16
0
65535
48
-
94
For development/production purposes
U8
0
225
49
-
95
For development/production purposes
U16
0
65535
50
-
74
For development/production purposes
U16
0
65535
51
-
75
For development/production purposes
U16
0
65535
52
-
1
For development/production purposes
U16
0
65535
53
Remote Data Bus Baud
Rate
6
Baud rate in 100’s (e.g. 1152 => 115200bps)
Can only be set via the BusLink service tool
U16
0
1152
54
Parity
81
Parity setting for Remote interface:
0 = No parity
1 = Even parity
2 = Odd parity
Can only be set via the BusLink service tool
U8
0
2
55
Number of Stop Bits
82
Stop bit setting for Remote interface:
1 = 1 stop bit
2 = 2 stop bits
Can only be set via the BusLink service tool
U8
1
2
56
-
98
For development/production purposes
U16
0
65535
57
-
47
For development/production purposes
U8
0
250
58
-
48
For development/production purposes
U8
0
250
59
Modbus Response Delay
99
Delay in ms from reception of last character in request
frame before response is sent
Default: 19200-1*11bit*3,5char = 2,005ms => 3ms
Can only be set via the BusLink service tool
U8
0
100
60
Command, Local
3
Can only be set via the BusLink service tool
U8
0
137
61
-
64
For development/production purposes
U32
0
4294967295
(31:16)
62
-
64
For development/production purposes
U32
0
4294967295
(15:0)
63
-
65
For development/production purposes
U16
0
65535
64
-
66
For development/production purposes
U16
0
65535