Before installation, de-installation or troubleshooting
• Stop the DL7/DL7R
• Switch off the power supply and pull out the mains plug.
• Relieve the DL7/DL7R of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• Make sure that the voltage at the control box is correct before the system is
connected to the mains.
• System connection. The individual parts must be connected before the control box
is connected to the mains. See the User Manual for LINAK actuators, if necessary.
During operation:
• If the control box makes unusual noises or smells switch off the mains voltage
immediately.
• Take care that the cables are not damaged.
• Unplug the mains cable on mobile equipment before it is moved.
• The products must only be used in an environment, that corresponds to their IP
protection.
Misc.
The actuator system has a sound level below 55dB(A) in typical applications.