Disposal of LINAK’s products

As LINAK’s customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that 
enables a classifi cation to different waste fractions for recycling or combustion.

Guidance

We recommend that our products be disassembled as much as possible and
divided into different waste groups for recycling or combustion.

For example, waste can be sorted into metals, plastics, cable scrap, combustible material, and recoverable resources.

Some of these main groups can be further divided into subgroups; e.g. metal can be divided into steel/aluminium/copper and 
plastic can be divided into ABS/PA/PE/PP.

As an example, the table below breaks down the different components in LINAK products to various recycling groups:

Product 

Components 

Recycling group

Columns/ Actuator : 

Spindle and motor 
Plastic housing 
Cable 
PCB boards 

Scrap
Plastic recycling or combustion
Cable scrap or combustion
Electronics scrap

Control Box : 

PCB boards 
Plastic housing 
Cable 
Transformer 

Electronics scrap
Plastic recycling or combustion
Cable scrap or combustion
Metal scrap

Handset/Control : 

Plastic housing 
Cable 
PCB board 

Plastic recycling or combustion
Cable scrap or combustion
Electronics scrap

By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents, if any.

Main groups of disposal

Product main groups 

Metal scrap

Cable scrap

Electronics scrap

Plastic recycling or 

combustin

Comments

DL7/DL7R

X

X

X

X

CBD4/CBD5/CBD6

X

X

X

X

DPXX

X

X

X

WDPL

X

X

X

Disposal of batteries

Details regarding safe disposal of used and leaking batteries:
Batteries should be disposed in accordance with appropriate federal, state and local regulations. LINAK recommends that 
used or leaking batteries are disposed through local recycling system. Please do not throw used or leaking batteries in normal 
household waste or in nature. This will cause damage to the enviroment. 

How to deal with leaking batteries.

Leaking batteries should be disposed as described above. 
If leaking batteries are discovered in the product the batteries must be removed at once to minimise damage to the product. 
If leaking batteries are left in the product it might become defect.
It is recommended to use plastic gloves when handeling leaking batteries. The contents of a leaking batteries can cause 
chemical burns and respiratory irritation. 
If exposed to the contents of a leaking battery, please wash with soap and water. If irritation persists, please seek medical 
attention. In case of eye contact, please flush eyes thoroughly with water for 15 minutes and seek medical attention."

Summary of Contents for Deskline DL7 system

Page 1: ...Page 1 of 24 LINAK COM DESKLINE DL7 system User manual...

Page 2: ...the DESKLINE system 6 Warranty 6 Maintenance 6 Description of the DESKLINE system 7 Mounting guidelines for the DL7 8 Mounting guidelines for the DL7R 9 Mounting guidelines CBD4 CBD5 CBD6 11 Electric...

Page 3: ...ucts leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiari...

Page 4: ...th the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and a...

Page 5: ...m connection The individual parts must be connected before the control box is connected to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unus...

Page 6: ...h reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who...

Page 7: ...K workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLIN...

Page 8: ...one which has been designed in such a way that it does not require a safety connection to electrical earth US ground The basic requirement is that no single failure can result in dangerous voltage bec...

Page 9: ...respective of the load the duty cycle 10 6 min hour or max 2 min at continuous use stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor and control box Exc...

Page 10: ...you to fasten the desk frame by means of 4 pcs of M8 screws of a good quality and a suitable length which must not go further into the motor housing than max 30 mm We advise you to use the 6 pcs of 6...

Page 11: ...you to fasten the desk frame by means of 4 pcs of M8 screws of a good quality and a suitable length which must not go further into the motor housing than max 30 mm We advise you to use the 6 pcs of 6...

Page 12: ...he monitor Magnets inside the motor may interrupt the picture on the monitor depending on the distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube o...

Page 13: ...CBD6 is equipped with two cable grooves improving the cable management when mounting The grooves can be used to bypass the CBD for both motorcables and the mains cable EU version only from one side to...

Page 14: ...o be connected to the sockets on the control box by means of the motor cables which have an 6 pin plug in each end Finally the mains cable is to be mounted and power switched on Please note that the c...

Page 15: ...the bottom position for each lifting unit Besides the system has to be initialised when exchanging the lifting units or the control box Forced initialisation under normal operation is done by driving...

Page 16: ...on Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents if any Main groups of disposal Product main groups Metal scrap Ca...

Page 17: ...Page 17 of 24 DL73R0B00470645 Label for DL7 Label for DL7R Label for CBD6 Label for CBD5 Label for CBD4...

Page 18: ...Page 18 of 24 DL7 DESKLINE DL7 System DRAWING APPENDIX...

Page 19: ...Page 19 of 24 DL7R CBD4 3 2 1 B AC B 4 278 80 100 6 119 62 51 247 5 5 5 5...

Page 20: ...Page 20 of 24 CBD5 CBD6...

Page 21: ...Page 21 of 24...

Page 22: ...der which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condition...

Page 23: ...Page 23 of 24...

Page 24: ...011 4303 8989 8900 Fax 011 4032 0184 www novotecargentina com Colombia MEM Ltda Tel 57 1 334 7666 Fax 57 1 282 1684 www mem net co India Mechatronics Control Equipments India Pvt Ltd Tel 91 44 2855848...

Reviews: