Connecting Multiple Silverpak17C’s
If using the
USB485
converter card, connect all the power and ground lines on the
units to the main power supply. Then daisy chain the RS485+ and RS485- lines prior
to plugging into the USB485 card. Be sure to also ground the USB485 card with Pin
2, ground.
All connections must be completed BEFORE applying power
.
Figure 7: Connection using USB485Converter Card
If using the
RS232-to-RS485
converter card, daisy chain all four wires: power,
ground, RS485+ and RS485- prior to plugging into the converter card.
Figure 6: Connection using RS232 Converter Card