background image

LASER

2

4

1

0

2

:

1

-

5

2

8

0

6

 

C

E

I

m

n

5

3

6

=

λ

=

.v

a

P

W

m

5

9

.

0

s

p

0

0

4

>

=

p

t

www.limit.se

LCA837092

L40

+

+

-

-

2 x AAA

1.

2.

2 sec 

1.

2.

3.

1 x 
2 x 

8.532 m

1
2
3
4

2 sec =

 OFF

   

0.000 m 

0‘00“1/16, 0 in 1/16

2 sec =

 UNIT

1 x 

=

2 x 

=

ON

ON

REF

UNIT

REF

UNIT

REF

UNIT

ON

FUNC

CLEAR

OFF

User Manual

Overview

Instrument Set-up

Introduction

The safety instructions and the user manual 

should be read through carefully before the 

product is used for the first time.

The person responsible for the product must 

ensure that all users understand these directions 

and adhere to them.

Technical data

* favourable conditions are: white and diffuse reflecting target 

(white painted wall), low background illumination and 

moderate temperatures.

** unfavourable conditions are: targets with lower or higher 

reflectivity or high background illumination or temperatures at 

the upper or lower end of the specified temperature range. 

***  Tolerances apply from 0.2 m to 5 m with a confidence 

level of 95%. 

With favourable conditions the tolerance may deteriorate by 

0.1 mm/m for distances above 5 m. 

With unfavourable conditions the tolerance may deteriorate 

by 0.15 mm/m for distances above 5 m.

Message Codes

If the message 

Error

 does not disappear after switching on 

the device repeatedly, contact the dealer.

If the message 

InFo

 appears with a number, press the Clear 

button and observe the following instructions:

Laser classification

Care

• Clean the device with a damp, soft cloth.

• Never immerse the device in water.

• Never use aggressive cleaning agents or solvents.

Areas of responsibility

Responsibilities of the person in charge of the 

instrument:

• To understand the safety instructions on the product and the 

instructions in the User Manual.

• To be familiar with local safety regulations relating to acci-

dent prevention.

• Always prevent access to the product by unauthorised 

personnel.

Responsibilities of the manufacturer of the original 

equipment: 

The company below is responsible for supplying the product, 

including the User Manual in a completely safe condition.

www.limit.se

Manuals on following languages are available on 

www.limit.se: Norwegian, Danish, Polish, Estonian, 

Lithuanian, Latvian, French, Greek, Italian, Dutch, German, 

Portuguese and Spanis

1) On / Measure

3) Measurement Reference / UNIT

2) Area / Volume

4) Clear / Off

Accuracy with favourable 

conditions *

± 2.0 mm  / ± 0.08 in ***

Accuracy with unfavourable 

conditions **

± 3.0 mm  / ± 0.12 in ***

Range with favourable 

conditions *

0.2-40 m  / 0.6-131 ft

Range with unfavourable 

conditions **

0.2-30 m  / 0.6-98 ft

Smallest unit displayed

1 mm  / 0.04 in

Laser class

2

Laser type

635 nm, < 1 mW

Ø laser point

at distances

6 / 18 mm

10 / 30 m

Protection class

IP54

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Battery durability (2 x AAA)

up to 5000 measurements

Dimension (H x D x W)

115 x 53 x 25 mm

4.5 x 2.14 x 1 in

Weight (with batteries)

95 g / 3.4 oz

Temperature range:

- Storage
- Operation

-25 to 70 °C

-13 to 158 °F

0 to 40 °C

32 to 104 °F

en

No. Cause

Correction

204 Calculation error

Perform measurement again.

252 Temperature too high

Let device cool down.

253 Temperature too low

Warm device up.

254 Battery voltage too low 

for measurements 

Change batteries.

255 Received signal too 

weak, measuring time 

too long

Change target surface (e.g. 

white paper).

256 Received signal too high Change target surface (e.g. 

white paper).

257 Too much background 

light

Shadow target area.

258 Measurement outside of 

measuring range

Correct range.

260 Laser beam interrupted Repeat measurement.

Wavelength

635 nm

Maximum radiant output 

power used for classification

0.95 mW

Pulse repetition frequency

320 MHz

Pulse duration

>400ps

Beam divergence

0.16 mrad x 0.6 mrad

Reviews: