LMS6002D Quick Starter Manual for Evaluation Board
61 |
P a g e
© Copyright Lime Microsystems
Rev: 2.2
Last modified: 03/05/2012
5.3
Receiver Setup and Basic Testing
Basic functionality checks on the receiver side are achieved by using the analogue output from
connector J3, not using the digital output from the data ADCs.
5.3.1.
Top Level Settings
Using the “Top Level” page, verify the “Rx DSM SPI” Clock Buffers and the “Soft Rx Enable”
Power Control is enabled in the menus as shown below. Also verify the RxOut/ADC in Switch is
set to Closed.
Figure 59 Top Level Settings