Suzhou Lily Tech. Co., Ltd.
Page 4. Total 5 pages
Humidity control
Humidify mode
【
h0 = H
】
When
Room humidity
≤
Set humidity
(
HP
) -
【
h1
】
, and
Humi. Output
(R2) has stopped for
【
h2
】
,
Humi. Output
(R2) will be energized.
When
Room humidity
≥
Set humidity
(
HP
),
Humi. Output
(R2) will be deenergized.
Dehumidify mode
【
t0 = P
】
When
Room humidity
≥
Set humidity
(
HP
) +
【
h1
】
, and
Humi. Output
(R2) has stopped for
【
h2
】
,
Humi. Output
(R2) will be energized.
When
Room humidity
≤
Set humidity
(
HP
),
Humi. Output
(R2) will be deenergized.
Over high humidity limit protection (only for humidify mode)
When
Room humidity
≥
Set humidity
(
HP
) +
【
h4
】
,
Fan Output
(R1) will be energized.
When
Room humidity
≤
Set humidity
(
HP
)
】
+
【
h4
】
-
【
h5
】
,
Fan Output
(R1) will be deenergized.
Turn egg control
(
R4, R5
)
Egg-Turn Output
will be energized (R4 and R5 alternatively) for
【
u1
】
after deenergized for
【
u0
】
,
periodically.
One
full egg turn
= one left turn (R4) + one right turn (R5).
There will be no egg turn after
full egg turn
has executed for
【
u2
】
times, and the egg turn signs will
blink.
Keeping
【
▲
】
depressed for 2 seconds starts manual egg right turning; keeping
【
▼
】
depressed for
2 seconds starts manual egg left turning.
Pressing
【
S
】
and
【
▼
】
simultaneously shows the
full egg turn
counter value.
Power on reset will reset the
full egg turn
counter value to zero.
Timer exhaustion control (R1)
Fan Output
(R1) will be energized for
【
u4
】
after deenergized for
【
u3
】
, periodically.
Warning control
When there is warning, the buzzer will beep.
The buzzer warning could be stopped/restored by pressing
【
P
】
.
High temp. warning: if
Room temp.
≥
Set temp.
(
TP
) +
【
t6
】
,
Room temp.
/“tHi” displays alternatively.
Low temp. warning: if
Room temp.
≤
Set temp.
(
TP
) -
【
t7
】
,
Room temp.
/“tLo” displays alternatively.
High humidity warning: if
Room humidity
≥
Set humidity
(
HP
) +
【
h6
】
,
Room humidity/
/“hH” displays
alternatively.
Low humidity warning: if
Room humidity
≤
Set humidity
(
HP
) -
【
h7
】
,
Room humidity/
/“hL” displays
alternatively.
The warning Press
【
P
】
Sensor
The
Room temp.
can be calibrated. If
Room temp.
is 0.2
℃ lower than real temp., set
【
t3
】
= 0.2
.
The
Room humidity
can be calibrated. If
Room humidity
is 2%RH higher than real, set
【
h3
】
= -2.
When sensor fails, the
Temp. and Humi. Output
(R3, R2) will be deenergized, and “E01” will display.
Note: do not plug in/off the sensor when power supplied.