Appendix D.
Trouble Shooting
5. The IP Fast Dome can not be accessed from a Web browser.
Note :
5-1. The IP address is already used by another device.
5-1-1. Disconnect your IP Fast from the network.
5-1-2. Run the PING utility (as described in PING Your IP Address, in Chapter Assign IP
Address by ARP) and follow the appropriate recommendations.
The assigned IP number can be assumed valid if the PING utility returns "request timed
out" in which case you should set the IP address again, power on the IP Fast Dome and
then try accessing the unit again.
67
Appendix D.
1. No Power
2. No Video
3. No Telemetry
4. Poor Focusing
1-1. Check power input connection
1-2. Check fuse on the PCB
1-3. Check connection between camera body and base
2-1. Check camera video output on camera
2-2. Check cable (damaged cable)
2-3. Check video input connection on monitor
2-4. Check 20PIN connection between camera body and base
3-1. Check camera ID switch setting
3-2. Check RS-485 cable IN / OUT connection on camera
3-3. Check RS-485 cable IN / OUT connection on keyboard
3-4. Check if the fast dome is under Auto Pan mode Please deactivate the Auto Pan
3-5. Check if alarm is triggered, Cancel triggered alarm
4-1. Dusts on dome cover or housing cover. Clean the cover with cotton cloth