Locking the castor wheels

To lock, press down on the wheel’s front lever. To release, 

lift the lever.

  

Helpful hint:

 When moving the lift system between two 

rooms where the doorway is narrower than 1440 mm / 

56.7 inch., FreeSpan can be moved zigzag, as in the  

illustration. 

FreeSpan UltraTwin is now lowered to the transport 

position and can be moved.

  

The length of the rail determines the max. load for the FreeSpan UltraTwin system. To maintain the max. load 

rating indicated on the rail, the lift units and accessories used must be approved for the same max. load or 

greater. The lift units’ max. load ratings vary according to model. See the instruction guides for the respective 

models. If a lifting accessory or lift unit with a max. load rating lower than that indicated on the rail is used, the 

max. load rating of the entire lift system is reduced to that of the accessory or lift unit. Read the label on the lift 

unit and lifting accessory, or contact a Liko representative.

Maximum Load

Summary of Contents for UltraTwin FreeSpan

Page 1: ...i seated or prone position only one lift unit is used FreeSpan UltraTwin is height adjustable to four posi tions and 8 different rail lengths are available allowing a total width of 2 to 5 5 metres To...

Page 2: ...sure that lifting accessories are not damaged The correct lifting accessory has been chosen with respect to type size material and version in relation to the needs of the patient The lifting accessory...

Page 3: ...When Likorall 243 ES or Likorall 250 ES are used the lift straps must be equipped with Q link to enable use of the Quick release Hook system on the intended lifting accessories Mounting of Likorall li...

Page 4: ...ght 23 5 upright 23 5 upright 24 2 rail 27 0 rail 29 8 rail 32 6 rail 35 5 rail 1 Note that the length of the rail determines the max load for the FreeSpan UltraTwin system The height of the FreeSpan...

Page 5: ...rchasing rails select the rail with carriage that is intended for use with Likorall lift units Before use study the instruction guide for the respective lift unit Loosen and remove the nuts and bolts...

Page 6: ...x total height is 2570 mm 101 2 inch Tighten the locking handles Repeat the procedure on the other side Mounting the charger The battery charger for Likorall can be installed on the charger mount on t...

Page 7: ...t it can also be used for lifting patients in a seated position Placement of FreeSpan UltraTwin During use FreeSpan UltraTwin should be positioned so that the rails are always centred as directly as p...

Page 8: ...il determines the max load for the FreeSpan UltraTwin system To maintain the max load rating indicated on the rail the lift units and accessories used must be approved for the same max load or greater...

Page 9: ...156086 Max 300 kg UltraTwist Slim Prod No 3126045 Incl handcontrol Max 500 kg UltraTwist Wide Prod No 3126047 Incl handcontrol Max 500 kg UltraStretch Prod No 3156058 Max 400 kg Accessories 800 cc Uni...

Page 10: ...onnel using original Liko spare parts Storage The lift system must be stored at a temperature above the freezing point and at normal relative humidity not exceeding 60 Service agreements Liko invites...

Reviews: