LD220
Serial timer (s)
This parameter sets the cycle time for the cyclic transmission of data set in the
parameter when using the serial output. The value is expressed in
seconds. In case of a serial request, the cyclic transmission is stopped for 20 s.
00.000
Cyclic transmission is switched off. The unit will
send data following a serial request or a “
7 – Serial
parameters on pages 76
and 78).
…
60.000
Cycle time expressed in seconds.
Serial value
This parameter sets the value to be transmitted.
0
:0
SSI position
1
:1
SSI Data
2
:2
SSI Single
3
:3
SSI Rev
4
:4
SSI Dir Result
5
::5
SSI Mask Result
6
:6
Minimal Value
7
:7
Maximal Value
8
:8
Result speed
9
:9
Result position
MODBUS
This parameter enables the Modbus protocol and allows to set the Modbus
address.
For details on the Modbus communication please refer to the “8 - Modbus RTU
Interface” section on page 87.
0
Modbus protocol is disabled: the serial interface is
using the Lecom protocol.
1 … 247
Modbus protocol is enabled: the serial interface is
using the Modbus RTU protocol.
The set value is the Modbus address of the device.
MAN LD220 E 1.4.odt
6 – Menus and parameters
73 of 100