SMA1
10 - Maintenance
The magnetic measurement system does not need any particular maintenance;
anyway it has to be handled with the utmost care as any delicate electronic
equipment. From time to time we recommend the following operations:
periodically check the soundness of the structure and make sure that there
are no loose screws; tighten them if necessary;
check the gap between the sensor and the magnetic scale all along the
whole measuring length. Wear of the machine may increase the tolerances;
the surface of the magnetic scale has to be regularly cleaned using a soft
and clean cloth to remove dust, chips, moisture etc.
MAN SMA1 E 2.9.odt
10 - Maintenance