SMA1
3 - Mounting instructions
WARNING
Installation has to be carried out by qualified personnel only, with power supply
disconnected and mechanical parts compulsorily in stop.
3.1 Overall dimensions
3.2 Magnetic scale
The sensor has to be paired with the
MTA1 type magnetic scale
only. For
detailed information on the MTA1 type scale and how to mount it refer to the
specific technical documentation.
Install the unit providing protection means against waste, especially swarf as
turnings, chips, or filings; should this not be possible, please make sure that
adequate cleaning measures (as for instance brushes, scrapers, jets of
compressed air, etc.) are in place in order to prevent the sensor and the
magnetic scale from jamming.
Make sure the mechanical installation meets the system's requirements of
distance, planarity and parallelism between the sensor and the scale indicated in
Figure 2 all along the whole measuring length.
The Figure 1 below shows how the sensor and the scale must be installed; the
arrow indicates the
standard counting direction
(increasing count, see the
WARNING
The system cannot work if mounted otherwise than illustrated in the Figures.
MAN SMA1 E 2.9.odt
3 - Mounting instructions
11 of 48