IF52
=
0
=
0
(Binary output)
=
1
(Gray coded output)
=
2
(BCD output)
=
0
(HIGH signal, normal output polarity)
=
1
(LOW signal, inverted output polarity)
Linear In (100%)
=
65 536
Linear Out (100%)
=
10 000
P1 (x)
=
000.0%
P1 (y)
=
000.0%
P2 (x)
=
100.0%
P2 (y)
=
100.0%
10.2.3 Free programmable linearisation
When you need to process the SSI encoder data and transform them into a
curve in the parallel output side (Linearisation), set the parameters as follows:
EXAMPLE
In the example a 16-bit SSI encoder provides 65,536 information to be
transformed into a programmable curve.
=
1
=
0
=
0
(Binary output)
=
1
(Gray coded output)
=
2
(BCD output)
=
0
(HIGH signal, normal output polarity)
=
1
(LOW signal, inverted output polarity)
P1 (x) … P16 (x)
=
% as required
P1 (y) … P16 (y)
=
% as required
This programmable feature allows the user to convert a linear motion to a non-
linear parallel output and vice versa. There are 16 programmable interpolation
MAN IF52 I_E 1.1.odt
10 – Scaling and linearisation functions
54 / 60