IF51
9 - PC set-up using OS3.2 operator software
Using a PC and our operator software OS3.2 the full set of functions for setting
up the unit is available. You can download this software and full instructions,
free of charge, from Lika Electronic website at the address www.lika.biz.
•
Connect your PC to the converter using a serial RS-232 cable having the
wire connection as shown in section “5.4 Serial interface“ on page 34.
Make sure the cable only connects pins 2, 3 and 5.
•
Start the OS3.x software, then the following screen will appear:
•
In case your text and colour fields remain empty and the headline shows
the message OFFLINE, then you must check your serial settings. To do
this, press the COMMS command in the menu bar. Ex factory, the unit
features the following serial standard settings:
Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit
•
If the serial settings of the unit should be unknown, you can run the
SCAN function from the TOOLS menu to find out them.
MAN IF51 I_E 1.1.odt
9 - PC set-up using OS3.2 operator software
40 / 56