EM58 PA
point = 4,096, then the encoder will provide a fixed voltage level of 0 V for the
33 552 384 positions before the origin of the travel (i.e. the point where you
press the
button); a voltage level between 0 V (origin of the
travel, position 0) and 5 V (end of the travel, position 4,095) for the positions of
the axis; a fixed voltage level of 5 V for the 33 552 384 positions after the last
point of the travel (i.e. the point where you press the
button).
To programme the encoder using the START / STOP (single ramp) programming
mode proceed as follows:
move the axis to the origin of the physical travel of the application you
want to measure and control; in other words, move it to the point where the
travel starts;
button; in this point the encoder will provide
the minimum current / voltage signal level available in the output range
selected in the
parameter;
now move the axis to the end of the physical travel of the application you
want to measure and control; in other words, move it to the point where the
travel stops;
button; in this point the encoder will provide
the maximum current / voltage signal level available in the output range
selected in the
MAN EM58 PA E 1.1
Software and configuration parameters
42 of 60