AMx58x P
MAN AMx58x P I_E 1.5.doc
Pag. 9/16
www.lika.it
www.lika.biz
User Manual
AMx58x P
Description
Lika’s Programmable Encoder is designed to be a
very flexible replacement for any absolute encoder
version with parallel or serial SSI output. The
encoder can be easily programmed via RS232
interface using any common terminal software (e.g.
Hyper Terminal®).
Contents
1
Safety summary
2
Identification
3
Installation
4
Mounting steps
5
Electrical Connections
6
Functions and settings
7
Dimensional drawing
1 ! Safety summary
•
Safety instructions serve for the protection of
health and safety standards at work and the
prevention of accidents. Please observe them
strictly.
•
Your device has been quality controlled, tested
and it’s ready for use. Please respect all
information and advices which are on the
device and on this manual.
•
Work on this device must only be carried out by
qualified personnel.
•
Repairs should be carried out only at our
factory. If any information is missing or unclear,
please contact the LIKA’s sales staff.
2 – Identification
The device can be identified by the label’s data
(ordering code, serial number). This information is
listed in the delivery document. The technical
features of the product can be determined by the
ordering code.
File: E211871
3 – Installation
Install the device according to the protection level
provided.
Protect it against knocks, dust, solvents and
extreme temperatures.
4 – Mounting steps
In order to guarantee the maximum life of
mechanical parts of the encoder, we recommend to
use a flexible coupling between the encoder and
the motor shaft.
IMPORTANT:
You are strongly recommended not
to carry out any mechanical operations (drilling,
milling…) on the encoder’s shaft. This could cause
serious damage to the internal parts and the
immediate warranty loss.
5 – Electrical connections
We recommend to follow the instructions below:
•
This device is to be supplied by a Class 2 Circuit
or LowAVoltage Limited Energy or Energy
Source not exceeding 30 Vdc.
•
While connecting, power must be switched OFF.
•
Check correct lines and connections before
switching ON the device.
•
We recommend that the device has to be
mounted as far as possible from any capacitive
or inductive noise source such as motors, relays