![Lightware RAP-B511-EU User Manual Download Page 24](http://html.mh-extra.com/html/lightware/rap-b511-eu/rap-b511-eu_user-manual_1915314024.webp)
4. Device Concept
RAP-B511 series
– User's Manual
24
Applied firmware package: v1.1.0b3b3 | LDC software: v2.5.1b5
Summary of the button operation modes
Momentary Operation Mode
PRESS
RELEASE
PRESS
RELEASE
interaction state
true
false
true
false
Toggle Operation Mode
PRESS
RELEASE
PRESS
RELEASE
interaction state
true
true
false
false
Radio Group Operation Mode
PRESS
RELEASE
PRESS
RELEASE
1
2
3
1
2
3
1
2
3
1
2
3
interaction state true false false
true false false
false true false
false true false
Flowchart of the button configuration process
INFO:
All settings of the button functions are available in the Lightware Device Contoller software (see
the details in
section) or via LW3 protocol commands (for more details see
section).
Interaction state
Changes /
not changes,
true / false
Momentary
Toggle
Radio Group
Operation mode
User interaction
Button press
Button release
Action
Executed
Not extecuted
4.2.2.
Rotary
The jog dial knob is designed for volume control (in a 16-level scale), but it can be used for other controlling
purposes, too.
Turning left and right the rotary
changes the volume value from 0
to 16. The volume values are the conditions, which are assigned
to the control commands (e.g. SET /MEDIA/PORTS/VIDEO/O2/
ANALOGAUDIO.VolumedB=-96\x0d\x0a). When the rotary reaches
the proper position, the action will be executed.
The control command can be sent over RS-232 or Ethernet (in this
case, the IP address of the target device is needed).
LWR Volume Control Schema
supports to load the LW3 command list automatically for controlling the volume
(and the mute/unmute state) of the Lightware devices. Choose the proper schema (see more details about
the compatibility table in
section) and fill the audio port number.
Custom Volume Control Schema
makes it possible to configure any command for controlling a third-party device.
Knob press
toggles between the muted and the unmuted states. When the
Custom
schema is loaded, press
and release event can be configure for any purpose.
Flowchart of the rotary configuration process
INFO:
Customizing the rotary functions is possible with Lightware Device Contoller software (the details
can be found in
section) or with LW3 protocol commands (for more details
see
section).
Volume control
schema
LWR
Custom
Ethernet
RS-232
Output:
Interface
Input:
User interaction
Rotary turn
Rotary press
Action
Mute /unmute,
volume up /
volume down
Any action