TL-3012 MEMORY CONTROL CONSOLE 

 Revision  0.6   

 

 

 

 

 

 

 

 

 

OWNERS MANUAL

 

          

12/17/2005 

www.lightronics.com 
Lightronics Inc.   

 

 

 

 

 

 

 

 

509 Central Drive  Virginia Beach,  VA  23454 

 

 

 

 

 

 TEL  757 486 3588 

 
MAINTENANCE AND REPAIR 

 
TROUBLESHOOTING 
 
Check that the multiplex cable is not defective. 
 
To simplify troubleshooting - set the unit to provide a  known set of conditions. 
 
Make sure that the dimmer address switches are set to the desired channels. 
 
OWNER MAINTENANCE 
 
The best way to prolong the life of your TL-3012 is to keep it dry, cool, clean, and COVERED when not in use. 
 
The unit exterior may be cleaned using a soft cloth dampened with a mild detergent/water mixture or a mild spray-
on type cleaner.  DO NOT SPRAY ANY LIQUID directly on the unit.  DO NOT IMMERSE the unit in any liquid or 
allow liquid to get into the controls.  DO NOT USE any solvent based or abrasive cleaners on the unit. 
 
The faders are not cleanable.  If you use a cleaner in them – it will remove the lubrication from the sliding 
surfaces.  Once this happens it is not possible to re-lubricate them. 
 
The white strips above the faders are not covered by the TL-3012 warranty.  If you mark on them with any 
permanent ink, paint, etc., it is likely that you will be unable to remove the markings without damaging the strips. 
 
There are no user serviceable parts in the unit.  Service by other than Lightronics authorized agents will void your 
warranty. 
 
EXTERNAL POWER SUPPLY INFORMATION 
 
The TL-3012 may be powered by an external power supply with the following specifications: 
 
 

Output Voltage:    13 to 25 Volts AC or DC 

 Output 

Current: 

 400 

Milliamps 

 Connector: 

  2.1mm 

female 

connector 

 
NOTE:  If a DC power supply is used – the center pin must be the NEGATIVE voltage. 
 
OPERATING AND MAINTENANCE ASSISTANCE 
 
Dealer and Lightronics Factory personnel can help you with operation or maintenance problems.  Please read the 
applicable parts of this manual before calling for assistance. 
 
If service is required -  contact the dealer from whom you purchased the unit or contact Lightronics,  Service 
Dept.,  509 Central Drive,  Virginia Beach,  VA  23454   TEL: (757) 486-3588. 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TL-3012

Page 1: ...TL 3012 MEMORY CONTROL CONSOLE OWNERS MANUAL Version 0 6 02 17 2005 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 TEL 757 486 3588...

Page 2: ...onnectors The TL 3012 is powered by the dimmer s which it is connected to It may also be powered via an optional external 13 VAC power supply DMX CONNECTIONS Connect the unit to a DMX dimmer using a c...

Page 3: ...ole output from all scenes channels and chases BLACKOUT Indicator Lighted when blackout is active MASTER Fader Adjusts output level of all console functions RECORD Button Used to record scenes and cha...

Page 4: ...ivate the scenes in any desired order Multiple scenes may be on at the same time including scenes from both banks A and B If multiple preset scenes are on then they will merge in a greatest of manner...

Page 5: ...ws While the chase is running move the CROSS FADER to set a fade time 0 100 of step duration then push CHASE FADE RATE to read the fader and lock in the rate To turn off a chase Push CHASE The Chase i...

Page 6: ...move the lubrication from the sliding surfaces Once this happens it is not possible to re lubricate them The white strips above the faders are not covered by the TL 3012 warranty If you mark on them w...

Page 7: ...red or defaced E This warranty does not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications...

Page 8: ...Lightronics Inc 509 Central Drive Virginia Beach VA 23454 20050125...