SCENE 7
CONTINUOUS DMX TRANSMISSION
SR516 will continue to send DMX string at 0 values
with no DMX input or no scenes active rather than no
DMX signal output
SCENE 8
DMX FAST TRANSMIT
Reduces the DMX interslot time to increase the DMX
transmission rate.
CONTROLLING EXCLUSIVE SCENE ACTIVATION
During normal operation multiple scenes can be active
at the same time. Channel intensities for multiple
scenes will combine in a "greatest of" manner.
You can cause a scene or multiple scenes to operate in
an exclusive manner by making them part of a
mutually exclusive group.
There are four groups which can be set. If scenes are
part of a group then only one scene in the group can
be active at any given time.
Other scenes (not part of that group) can be on at the
same time as scenes in a group.
Unless you are going to set one or two simple groups
of non-overlapping scenes you may want to
experiment with the settings to get different effects.
SETTING SCENES TO BE PART OF A MUTUALLY
EXCLUSIVE GROUP
(Function Codes 41 - 44)
After accessing a function (41 - 44) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The scene lights will show which scenes are part of
the group. Use the
BANK A/B
button as needed to
check both banks.
2. Use the scene buttons to toggle scenes on/off for
the group.
3. Push
REC to save the new group set.
FACTORY RESET
(Function Code 88)
A Factory Reset will invoke the following conditions:
1. All scenes will be erased.
2. All fade times will be set to two seconds.
3. Simple switch functions will be set as follows:
Input #1 Turn ON Scene 1
Input #2 Turn OFF Scene 1
Input #3 Toggle Scene 2 ON and OFF
4. All System Configuration Options (Function
Codes 37 and 38) will be turned OFF.
5. Mutually Exclusive groups will be cleared (no
scenes in the groups).
TO PERFORM A FACTORY RESET:
After accessing a function (88) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The
OFF (0)
light will repeat a pattern of 4
flashes.
2. Enter
0516
(the model number of the product).
3. Push
REC
. The scene lights will flash briefly
and the unit will return to its operating mode.
OPERATION
The SR516 turns on automatically when power is
applied from the external power supply. There is no
ON/OFF switch or button.
When an SR516 is not powered, a DMX signal fed to
the DMX IN connector (if connected) is directly
routed to the DMX OUT connector.
DMX INDICATOR LIGHT
This indicator conveys the following information
about the DMX input and DMX output signals.
1. OFF
DMX is NOT being received.
DMX is NOT being transmitted.
(No scenes are active).
2. BLINKING DMX is NOT being received.
DMX IS being transmitted.
(One or more scenes are active).
3. ON
DMX is being received.
DMX is being transmitted.
SCENE BANKS
The SR516 can store 16 operator created scenes and
activate them with the push of a button. Scenes are
organized in two banks (A and B). A bank switch
button and indicator are provided for switching
between banks. Bank "B" is active when the
BANK
A/B
light is on.