background image

PAR

4

  

 

 

 

 

 

 

 

 

 

 

INSTRUCTION MANUAL

 

          

 

 

 

Page 

 

of 

 

MULTIPLE LENS PAR FIXTURE

                   

 

  

Version 

20100224 

 

LENS REMOVAL 

 

1.  Place the fixture on a horizontal surface with the 
 lens 

down. 

 

2.  Turn the lens rotation ring until the metal release 
  tab is 90

º

 away from the gel retaining clip on the 

 housing. 

 

3.  Hold one hand under the lens and press the metal 
  release tab to release it.  Allow the lens to carefully 
  drop out of the fixture. 

 

LENS INSTALLATION 

 

1.  Place the fixture on a horizontal surface. 

 

2.  Turn the lens rotation ring until the metal release 
  tab is 90

º

 away from the gel retaining clip on the 

 housing. 

 

3.  Slide the one edge of the lens edge under the fixed 
  tabs on the lens rotation ring. 

 

4. Press the other edge of the lens down until it is 
  captured by the metal release tab of the rotation 
 ring. 
 

OPERATION 

 
    CAUTION 

HOT 

SURFACES 

 

 

 

 

Do not touch any part if the fixture    

 

 

 

 

during operation.  It can operate at    

    temperatures 

which 

can 

cause 

severe 

 

    burns. 

 

Do not operate the lamp unless the lamp holder is 
installed in the fixture! 

 

The lens and gel holder must be installed when the 
fixture is operating. 

 

Do not project the beam onto nearby flammable 
surfaces. The minimum distance is 5 meters.  

 

The lens may be rotated to adjust beam alignment.  
This is done by rotating the lens rotation ring located 
near the front of the fixture. 

 

Once correctly installed, the fixture may be operated 
by applying power via a dimmer or other compatible 
power. 
 
Switching the lamp on and off at short intervals will 
reduce the life of both the lamp and the fixture. 
 
 

MAINTENANCE 

 
 

 

 

 

CAUTION  RISK OF ELECTRIC SHOCK 

 

 

 

 

Disconnect the fixture from power    

    before 

handling. 

 
 
 

 

 

 

CAUTION - HOT SURFACES

 

 

 

 

 

Allow the fixture to cool off before    

    handling. 

 

 
To ensure the reliability of the fixture it should be kept 
clean. The lens and reflector should be regularly 
cleaned to maintain an optimum light output. 

 

Do not use any organic solvent, e.g. alcohol, to clean 
the housing.

  

Do NOT use glass cleaner or any type of 

solvent on the reflector. When cleaning the reflector 
use a damp, clean, soft, lint-free cotton cloth with a 
mild, soapy water solution and gently wipe the 
reflector, and then remove any soapy water residue 
with a clean, soft, lint-free cotton cloth.  

 

Do not use rough surface materials to wipe the 
reflector.

   

Cleaning frequency depends on the 

environment in which the fixture operates.  Moisture, 
smoke or particularly dirty surroundings can cause 
greater accumulation of dirt on the unit’s optics. It is 
recommended that the lens be cleaned at least once 
every 20 days. Clean the reflector at least once every 
30 / 60 days. 
 

TECHNICAL SPECIFICATIONS 
 

Power Supply: 120 VAC, 60 Hz  
Power Consumption: 800 Watts MAX 
Dimensions: 255mm D  x  280mm W  x  290mm H 
Weight: 4 kg 
Lamp: OSRAM GLA/575 or GLE/750 (G9.5 Base) 
Maximum Ambient Temperature: 45° C 
Maximum Housing Temperature: 160° C 

 
 
 
 
 