background image

 
                               

 

 

Page 

 

of 

 

 

 

 

 

 

 

 

 

 

 

 

 

FXLD136RGB LED FIXTURE 

 

Version 0.1  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

 

 12/29/2010 

www.lightronic.com 
Lightronics 

Inc. 

         509 

Central 

Drive 

 

Virginia 

Beach, 

Va 

 

234354 

       

 

757 

486 

3588 

DMX TERMINATION 

 

A DMX chain should be terminated at the last 
receiving device on the chain.  This is done by 
installing a commonly available 1/4 Watt, 120 Ohm 
resistor across the DATA - and DATA + wires at the 
last device.  If you have only a few fixtures very close 
together and a very short run to the controller then you 
may be able to operate without the terminator. 

 

OPERATION 

 

Operating options are set using the LED display and 4 
buttons 

(MENU, ENTER, UP, DOWN)

 on the rear of 

the fixture. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Push 

MENU

 to access the operating options. Then use 

UP

 

and 

DOWN

 to scroll through the available choices.  

When you reach the option you want to set or change - 
push 

ENTER

.

  Now you can view the current setting 

for the option and or change it. Push 

ENTER

 to save 

your changes.  Push 

MENU

 to return to the current 

option  display. See the "MENU NAVIGATION" 
diagram for additional details. 

 

There are 5 main operation modes:  DMX, Manual, 
Auto,  Sound,  Master/Slave 

 

DMX OPERATION 

 

Use the 

ADDR

 menu to set the starting address of the 

unit.  You can set the starting address of the unit with 
the 

UP

 and 

DOWN

 buttons. 

 
 

The fixture uses three channels with allocations as 
follows: 

 

CHANNEL 1:   0 - 255  Red level (255  = maximum) 
CHANNEL 2:   0 - 255  Green level (255  = maximum) 
CHANNEL 3:  0 - 255  Blue level (255  = maximum) 

 

MANUAL OPERATION 

 

For manual operation the level red, green, and blue 
LEDs may be independently controlled.  Use the 

rL-

-

gL--, 

and 

bL--

, menus to set the levels.  The range is 

from 00 (OFF) to 12 (Full On). 

 

AUTO OPERATION 

 

Auto operation includes 3 sub modes:  Flash (strobe), 
Auto Fade, and Auto Sequence. 

 

AUTO FLASH 

 

The Auto Flash mode flashes the current color.  Use 
the 

FLAS

 menu to set the flash speed and activate the 

option. The range is from 00 to 12. 12 is fastest. 

 

AUTO FADE 

 

The Auto Fade mode cycles smoothly through a 
sequence of seven colors.  Use the 

FADE

 menu to set 

the speed and activate the option.  The range is from 00 
to 12.  12 is fastest. 

 

AUTO SEQUENCE 

 

The AUTO SEQUENCE  mode switches through a 
sequence of seven colors.  Use the 

ASC-

 menu to set 

the sequence speed  and activate the option.  The range 
is from 00 to 12.  12 is fastest. 

 

SOUND OPERATION 

 

Sound operation has a Color and a Flash submode. 

 

Use the 

SOUA

 menu to invoke the Sound Color  

option.  The unit will sequence through  a series of 
colors in sync with music base notes. 

 

Use the 

SOUF

 menu to invoke the Sound Flash 

option.  The unit unit will flash through  a series of 
colors in sync with music base notes. 
 

MASTER/SLAVE OPERATION 

 

Connect the units together using DMX cables.  Set all 

FXLD136RGB  REAR VIEW 

Summary of Contents for FXLD136RGB

Page 1: ...he FXLD136RGB has a line cord for connection to a 120 VAC 15 Amp 60Hz grounded service The safety ground pin on the power cord must be used DMX CONNECTIONS A system using DMX control should be connected as a chain of devices In other words the control signal cable should proceed from the controller to the first receiving device and then to others in a continuous daisy chain fashion The fixture has...

Page 2: ... buttons The fixture uses three channels with allocations as follows CHANNEL 1 0 255 Red level 255 maximum CHANNEL 2 0 255 Green level 255 maximum CHANNEL 3 0 255 Blue level 255 maximum MANUAL OPERATION For manual operation the level red green and blue LEDs may be independently controlled Use the rL gL and bL menus to set the levels The range is from 00 OFF to 12 Full On AUTO OPERATION Auto operat...

Page 3: ...ol cable Check the address settings of the unit and the controller REPAIR The only FXLD136RGB user serviceable part is a 5mm x 20mm externally accessible fuse DISCONNECT THE UNIT FROM POWER BEFORE CHECKING OR REPLACING THE FUSE Replace fuse ONLY with 1 0 Amp 250VAC fast blow fuse Internal service on the unit by other than Lightronics authorized agents will void the warranty If service is required ...

Page 4: ...Page 4 of 6 FXLD136RGB LED FIXTURE Version 0 1 OWNERS MANUAL 12 29 2010 www lightronic com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 MENU NAVIGATION ...

Page 5: ...erves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied Lightronics is not responsible for supplying new equipment in accordance with any earlier...

Page 6: ...www lightronic com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 ...

Reviews: