background image

 
                               

 

 

 

Page 

 

of 

 

 

 

 

 

 

 

 

 

 

 

 

 

FXLD100ECMY26B LED FIXTURE 

 

Version 0.1  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

       

04/25/2012 

www.lightronics.com 

Lightronics 

Inc. 

        509 

Central 

Drive 

 

Virginia 

Beach, 

Va 

 

234354 

        

 

 

757 

486 

3588

 

DMX TERMINATION 

 

A DMX chain should be terminated at the last 
receiving device on the chain.  This is done by 
installing a commonly available 1/4 Watt, 120 Ohm 
resistor across the DATA - and DATA + wires at the 
last device.  If you have only a few fixtures very close 
together and a very short run to the controller then you 
may be able to operate without the terminator. 

 

OPERATION 

 

A power ON/OFF switch is located at the rear of the 
unit.  A control panel on the back of the unit is used to 
set the operating options.  It consists of an LED display 
and four buttons 

(MODE, SAVE, UP, and DOWN)

 

 
 
 
 

 
 
 
 
 
 
 

Push MODE to access the operating options. Then use 

UP

 

and 

DOWN

 to scroll the available choices.  When 

you reach the value you want to set - push 

SAVE

.

   

 

There are 3 operation modes:  DMX, F1, and F2.  

 

DMX OPERATION 

 

Use the 

A - - -

 

menu to set the starting address of the 

unit.  You can set the starting address of the unit with 
the 

UP

 and 

DOWN

 buttons. 

 

The fixture uses seven DMX channels with allocations 
as follows: 

 

CHANNEL 1:   Iris Control 
CHANNEL 2:   Cyan Filter 
CHANNEL 3: 

Magenta Filter 

CHANNEL 4: 

Yellow Filter 

CHANNEL 5: 

CTO Filter 

CHANNEL 6: 

Master Dimmer Level 

CHANNEL 7: 

Strobe Rate

 

 

Additional detail on DMX channel operation is given 
in the table "DMX Values and Functions". 

 

AUTO MODES F1 and F2 

 

The AUTO MODES switch continuously through a 
sequence of  colors.

   

Both F1 and F2 mode may be 

turned on or off independently from the control panel. 

 

A DMX signal must be present but is not used when 
operating in F1 or F2 modes. 

 

MAINTENANCE AND REPAIR 

 

 
 
 
 
 
 
TROUBLESHOOTING 

 

Check that you have power applied to the unit. 

 

Check the DMX control cable. 

 

Check the address settings of the unit and the 
controller. 

 

CLEANING 

 

Do not use harsh chemicals or solvents when cleaning 
the fixture.  A mild detergent can be used sparingly if 
needed.  Ensure that the unit is completely dry before 
re-u

se. 

 

REPAIR 

 

The only FXLD100ECMY26B user serviceable part is 
a 5mm x 20mm externally accessible fuse.   

 

DISCONNECT THE UNIT FROM POWER BEFORE 
CHECKING  OR REPLACING THE FUSE 

 

Replace fuse 

ONLY

 with 3.15 Amp, 250VAC, fast 

blow fuse. 

 

Internal service on the unit by other than Lightronics  
authorized agents will void the warranty. 

 

If service is required, contact the dealer from whom 
you purchased the item, or  contact the Lightronics, 
Service Department,  509 Central Drive,  Virginia 
Beach, VA 23454.  Tel: 757 486 3588. 

 

 

MODE 

UP 

DOWN

SAVE 

CONTROL PANEL 

CAUTION    DO NOT OPEN UNIT  

RISK OF ELECTRIC SHOCK 

RISK OF FIRE 

Reviews: